Siemens 3RT2016-1AK62 SIRIUS Power Contactor, Size S00, 24V

MPN3RT2016-1AK62
Active

Siemens SIRIUS 3RT2016-1AK62 power contactor, Size S00, 24 V coil, screw terminals, 45 mm width, DIN rail mount.

$17.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-1AK62 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-1AK62 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-1AK62 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2016-1AK62 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-1AK62 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-1AK62 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-1AK62 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-1AK62 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-1AK62 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2016-1AK62 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The 45 mm width keeps the fill factor tight on a crowded rail.

Mounting and mechanical fit

That 6 mm side gap is tighter than some contactors — worth checking if you're packing multiple units side-by-side in a dense panel. Dimensions: 58 mm high, 45 mm wide, 73 mm deep.

Electrical ratings and switching performance

Rated operational current at 24 V is 10 A, dropping to 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. For motor starting duty (AC-3), the maximum switching frequency is 750 operations per hour; for AC-4 (plugging/reversing) it's 250 per hour. AC-1 resistive loads can run at 1000 per hour. That -25 °C lower limit is fine for most heated plant floors but marginal for unheated warehouses in cold climates — plan the enclosure heater accordingly.

Screw-type terminals accept solid conductors from 0.5 to 4 mm², stranded from 0.5 to 4 mm². For two-wire connections: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm². The auxiliary switch is included, so no separate add-on for basic status feedback.

Frequently asked questions

What are the key dimensions for panel layout?

Height 58 mm, width 45 mm, depth 73 mm. Required clearances: 10 mm upwards, 10 mm forwards, 10 mm downwards, 6 mm at the side. The 45 mm width and 73 mm depth fit standard 200 mm deep enclosures with room for wiring.

What wire sizes does the screw terminal accept?

Solid: 0.5 to 4 mm². Stranded: 0.5 to 4 mm². For two conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm².

What is the maximum switching frequency for motor loads?

AC-3 duty: 750 operations per hour. AC-4 duty: 250 operations per hour. AC-1 resistive loads: 1000 operations per hour.

MPN
3RT2016-1AK62