Siemens 3RT2016-1AP62 SIRIUS Power Contactor, 24 VDC coil, S

MPN3RT2016-1AP62
Active

Siemens SIRIUS power contactor, 3RT2016-1AP62, Size S00, 24 VDC coil, screw terminals, 45 mm wide, snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-1AP62 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-1AP62 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-1AP62 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz220 V
3RT2016-1AP62 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-1AP62 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-1AP62 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-1AP62 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-1AP62 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-1AP62 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2016-1AP62 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

Rated for AC-3 switching duty (motor starting) at 750 operations per hour, and up to 1 000 1/h for AC-1 resistive loads. The AC-4 (plugging/reversing) rate is lower at 250 1/h — a typical constraint for contactors this size when handling inching duty. The auxiliary contact set is rated for 10 A at 24 V, 3 A at 400 V, and down to 0.2 A at 440 V — enough for PLC digital inputs or small relay coils in most 24 VDC control circuits.

The 45 mm width (three 15 mm modules) and 58 mm height fit standard panel layouts. Wire terminals are screw-type, accepting solid or stranded conductors from 0.5 to 4 mm² (single) or two conductors per terminal (2x 0.5...1.5 mm², 2x 0.75...2.5 mm², 2x 4 mm²). No special ferrules required for stranded, but they help in multi-wire terminations.

Environmental and life ratings

Mechanical life is typical 30 000 000 operations — the contactor will outlast the machine's service life in most cycling applications. Switching frequency limits are per duty class, so match the load profile to the rating.

Frequently asked questions

What are the key dimensions for panel layout?

Width 45 mm, height 58 mm, depth 73 mm. Clearances: 10 mm upward/forward/downward, 6 mm at sides.

What wire sizes does the screw terminal accept?

Solid or stranded 0.5...4 mm² single, or two conductors up to 2x 4 mm² per terminal.