3RT2016-1FB41-ZX95
CONTACTOR, AC-3, 4KW/400V, 1NO, 24V DC, W INTEGRATED DIODE 3POL, ASM S00 SCREW TERMINAL REUSABLE, 72 UNITS
Specifications
| Parameter | Value |
|---|---|
| Contactor frame size | S00 |
| Parameter | Value |
|---|---|
| Rated operational current, AC-12, max. | 10 A |
| Rated operational current, AC-4 @ 400 V | 8.5 A |
| Rated value @ 400 V | 3 A |
| Rated value @ 500 V | 2 A |
| Rated value @ 690 V | 1 A |
| Rated value @ 230 V | 1 hp |
| Rated value @ 24 V | 10 A |
| Rated value @ 60 V | 2 A |
| Rated value @ 110 V | 1 A |
| Rated value @ 220 V | 0.3 A |
| Parameter | Value |
|---|---|
| Control supply voltage type | DC |
| Parameter | Value |
|---|---|
| Main poles | 3 |
| Main NO contacts | 3 |
| Auxiliary contact reliability | 1 faulty switching per 100 million (17 V, 1 mA) |
| Parameter | Value |
|---|---|
| Short-circuit coordination type 1, fuse | gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA) |
| Short-circuit coordination type 2, fuse | gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA) |
| Aux. switch short-circuit protection, fuse | gG: 10 A (500 V, 1 kA) |
| Parameter | Value |
|---|---|
| Main circuit connection | screw-type terminals |
| Aux. / control circuit connection | screw-type terminals |
| Conductor cross-section, solid | 0.5 ... 4 mm² |
| Conductor cross-section, solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² |
| Conductor cross-section, finely stranded w/ ferrule | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Mounting method | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 |
| Side-by-side mounting | Yes |
| Parameter | Value |
|---|---|
| Durability (operating cycles, typ.) | 30 000 000 |
| Durability with aux. switch block (cycles, typ.) | 10 000 000 |
| Parameter | Value |
|---|---|
| Operating temperature range | -25 ... +60 °C |
| Storage temperature range | -55 ... +80 °C |
| Installation altitude, max. | 2 000 m |
| Parameter | Value |
|---|---|
| Width | 45 mm |
| Height | 58 mm |
| Depth | 73 mm |
Frequently asked questions
What is the coil voltage of the Siemens 3RT2016-1FB41-ZX95 contactor?
Coil voltage must match panel control supply before commissioning or the contactor will not pull in.
What does the -ZX95 suffix mean on Siemens 3RT2016-1FB41?
The suffix encodes reusable packaging (72 units) which affects ordering, logistics, and unit cost.
What is the difference between 3RT2016-1BB41 and 3RT2016-1FB41-ZX95?
Engineers and buyers need a like-for-like swap map when substituting or comparing motor-load contactors.
How many poles does the 3RT2016-1FB41-ZX95 contactor have and what is its AC-3 rating?
Pole count and motor rating determine fit for 3-phase motor switching up to 4kW at 400V.
Where can I download the datasheet for Siemens 3RT2016-1FB41-ZX95?
Datasheet confirms wiring diagram, terminal torque, and approvals needed for panel design and inspection.
What are compatible alternatives or cross-references for the 3RT2016-1FB41-ZX95?
Sourcing buyers need drop-in or functionally equivalent options when stock or lead time is constrained.