Siemens 3RT2016-2AB01-ZW97 — Contactors

Siemens 3RT2016-2AB01-ZW97 SIRIUS Power Contactor, Size S00,

MPN3RT2016-2AB01-ZW97
Active

Siemens SIRIUS power contactor, size S00, 45 mm width, spring-type coil terminals, AC-3 rated, currently in production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2016-2AB01-ZW97 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-2AB01-ZW97 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-2AB01-ZW97 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz24 V
3RT2016-2AB01-ZW97 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-2AB01-ZW97 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-2AB01-ZW97 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-2AB01-ZW97 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-2AB01-ZW97 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-2AB01-ZW97 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2016-2AB01-ZW97 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

That helps when you're squeezing it into a crowded panel. Dimensions are 70 mm high, 45 mm wide, 73 mm deep.

Termination & Wiring

Main contact terminals accept solid or stranded wire from 0.5 to 4 mm², with a 2x (0.5 to 4 mm²) capacity for paralleling conductors. The coil connection uses spring-type terminals — no screwdriver needed for the magnet coil, which speeds up panel wiring. Keep those minimums for arc flash and heat dissipation, especially at higher switching frequencies.

Switching Performance & Ratings

Rated for AC-3 duty (motor switching) at 750 operating cycles per hour maximum, and AC-1 (resistive) at 1,000 cycles/h. AC-4 (plugging/reversing) drops to 250 cycles/h. Arcing time runs 10 to 15 ms at AC. Motor horsepower rating: 1 hp at 230 V. For DC switching, the ratings are 10 A at 24 V, dropping to 0.2 A at 440 V — that's typical for a contactor this size; don't expect it to handle heavy DC loads.

Environmental Limits

Frequently asked questions

What are the key dimensions for panel layout?

The contactor is 70 mm high, 45 mm wide, and 73 mm deep. Minimum clearance: 10 mm up/down/forward, 6 mm at the sides.

What wire sizes does the main contact accept?

Solid or stranded wire from 0.5 to 4 mm², with a 2x (0.5 to 4 mm²) capacity for paralleling two conductors per terminal.

What is the switching frequency for motor loads?

AC-3 (motor) duty: 750 operating cycles per hour maximum. AC-4 (plugging/reversing): 250 cycles/h. Mechanical life is typical 30 million operations.

Does this contactor include an auxiliary switch?

Yes, the -ZW97 variant includes an auxiliary switch as standard.

MPN
3RT2016-2AB01-ZW97