Skip to main content
Siemens 3RT2016-2AK61-ZW97 — Contactors

3RT2016-2AK61-ZW97 - Siemens

MPN3RT2016-2AK61-ZW97
Active

CONTACTOR, AC-3, 4KW/400V, 1NO, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SPRING-LOADED TERMINAL MULTI-UNIT PACKAGING 32 PIECES

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-2AK61-ZW97 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-2AK61-ZW97 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-2AK61-ZW97 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2016-2AK61-ZW97 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-2AK61-ZW97 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-2AK61-ZW97 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-2AK61-ZW97 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-2AK61-ZW97 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-2AK61-ZW97 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2016-2AK61-ZW97 — Specifications
ParameterValue
At AC4 ... 15 ms

Frequently asked questions

What does the ZW97 suffix mean on the Siemens 3RT2016-2AK61?

Buyers need to confirm the suffix denotes the 32-unit multi-pack with spring terminals before ordering the correct variant.

What is the coil voltage of the Siemens 3RT2016-2AK61-ZW97?

Mistakes on 110V 50Hz / 120V 60Hz coil selection cause panel rework, so the exact rating must be verified.

How many contactors are in the 3RT2016-2AK61-ZW97 multi-unit package?

Determines whether the SKU is suitable for spares stocking, panel runs, or single-unit replacement.

What is the difference between 3RT2016-2AK61 and 3RT2016-2AK61-ZW97?

Clarifies whether the ZW97 variant changes specification or only packaging to avoid duplicate orders.

What are the AC-3 ratings and frame size of the 3RT2016-2AK61-ZW97?

Confirms 4kW @ 400V on size S00 suits the motor load and DIN-rail layout before integration.

Where can I buy the Siemens 3RT2016-2AK61-ZW97 with current stock and pricing?

Procurement teams need a live supplier and lead-time check before releasing the purchase order.

MPN
3RT2016-2AK61-ZW97