Specifications

3RT2016-2AN21 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-2AN21 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-2AN21 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz220 V
3RT2016-2AN21 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-2AN21 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-2AN21 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-2AN21 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-2AN21 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-2AN21 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2016-2AN21 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The coil terminals use spring-type connections, so you land the control wiring without a screwdriver — speeds up panel build and avoids loose terminations on a vibrating line.

The 20-12 A main contact range covers the AC-3 motor switching duty for fractional-horsepower loads. The 1 hp rating at 230 V tells you it handles a typical small motor on a 230 V single-phase supply — common on packaging lines for infeed belts or label applicators. Switching frequency limits are per duty class: up to 1000 cycles/hour in AC-1 (resistive), 750 in AC-3 (motor start/run), and 250 in AC-4 (plugging/inching). If your application does frequent reversing or jogging, the AC-4 limit governs — don't exceed 250 operations per hour.

The Size S00 footprint — 45 mm wide, 70 mm tall, 73 mm deep — fits standard panel layout grids. Wire range accepts 0.5 to 4 mm² solid or stranded, or 2x (0.5 to 4 mm²) for looping through.

Auxiliary contacts and coil data

An integrated auxiliary switch is standard — no add-on block needed for basic status feedback. Auxiliary contact ratings vary by voltage: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.2 A at 440 V. Operating time is 4-15 ms AC; arcing time is 10-15 ms. Mechanical service life is typically 30 million operations.

Frequently asked questions

What are the key ratings for the 3RT2016-2AN21?

Main contacts rated 20-12 A, motor rating 1 hp at 230 V. Coil holding power 0.25 VA at 50/60 Hz. Integrated auxiliary switch with ratings from 10 A at 24 V down to 0.2 A at 440 V. Mechanical life typically 30 million operations.

What wire sizes does the 3RT2016-2AN21 accept?

Solid or stranded wire from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for looping. Coil terminals are spring-type — no screwdriver needed for control wiring.

What is the mounting footprint and clearance for the 3RT2016-2AN21?

Size S00: 45 mm wide, 70 mm tall, 73 mm deep. Mounts on 35 mm DIN rail per DIN EN 60715. Clearances: 10 mm up/down/forward, 6 mm sides. Mounting position flexible with +/-180° rotation and +/-22.5° tilt.

MPN
3RT2016-2AN21