Skip to main content
Siemens 3RT2016-2AP02-ZW97 — Contactors

Siemens SIRIUS 3RT2016-2AP02-ZW97 Power Contactor, Size S00,

MPN3RT2016-2AP02-ZW97
Active

Siemens SIRIUS 3RT2016-2AP02-ZW97 power contactor, Size S00, 24 VDC coil, spring-type terminals, 45 mm wide, 70 mm high, 73 mm deep.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-2AP02-ZW97 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-2AP02-ZW97 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-2AP02-ZW97 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2016-2AP02-ZW97 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-2AP02-ZW97 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-2AP02-ZW97 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-2AP02-ZW97 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-2AP02-ZW97 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-2AP02-ZW97 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2016-2AP02-ZW97 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The Siemens SIRIUS 3RT2016-2AP02-ZW97 is a Size S00 power contactor with a 24 VDC coil and spring-type terminals — a compact 45 mm wide unit designed for screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. It belongs to the SIRIUS family, Siemens' modular contactor line for motor switching and general load control in industrial control panels. The spring-type terminals accept solid or stranded conductors from 0.5 to 4 mm² (2x per clamp), and the mounting position is flexible: +/-180° rotation on a vertical surface, plus +/-22.5° tilt forward/backward. This gives panel builders room to fit it into tight enclosures without rewiring constraints.

Switching Capability and Duty Cycles

Maximum operating frequency varies by duty: 1,000 switching cycles per hour under AC-1 (resistive load), 750/h under AC-2 and AC-3 (motor starting/running), and 250/h under AC-4 (plugging/inching). The AC-3e rating matches the AC-3 limit at 750/h. These limits define the thermal cycling the contactor can sustain — exceeding them accelerates contact wear. Auxiliary contact ratings are provided across multiple voltages: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. The arcing time spans 10 to 15 ms. These values matter for control circuit coordination — the auxiliary switch can handle pilot duty loads within those limits.

Physical footprint: 45 mm wide, 70 mm high, 73 mm deep. These spacing figures govern heat dissipation and arc flash clearance in a DIN-rail enclosure. The storage limit is a handling spec, not an operating one — the contactor can survive colder warehouse conditions than it can run in.

MPN
3RT2016-2AP02-ZW97