Skip to main content
Siemens 3RT2016-4AG61 — Contactors

Siemens 3RT2016-4AG61 SIRIUS S00 Power Contactor, 24 VDC Coi

MPN3RT2016-4AG61

Siemens SIRIUS S00 power contactor, 3RT2016-4AG61, 24 VDC coil, screw and snap-on DIN rail mount, auxiliary switch, 45 x 58 x 73 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-4AG61 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-4AG61 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-4AG61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz100 V
3RT2016-4AG61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-4AG61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-4AG61 — Connection & Mounting
ParameterValue
Main circuit connectionRing cable lug connection
Aux. / control circuit connectionring terminal lug connection
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-4AG61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-4AG61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-4AG61 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2016-4AG61 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

SIRIUS S00 power contactor — 3RT2016-4AG61

The S00 frame size keeps the footprint compact at 45 mm wide, 58 mm tall, and 73 mm deep — a space-saving fit for high-density panel layouts where every DIN rail slot counts.

The auxiliary contact is rated for switching at multiple voltage levels: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.2 A at 440 V, 7.6 A at 480 V, and 2 A at 500 V. Switching frequency limits vary by duty class: 1,000 operations per hour at AC-1 (resistive loads), 750 ops/h at AC-2 and AC-3 (motor starting/running), and 250 ops/h at AC-4 (plugging/inching). For a conveyor line cycling every 5 seconds, the AC-3 limit of 750 ops/h means the contactor can handle about one start every 4.8 seconds — match your application cycle time against this ceiling. The 10 mm clearance required upwards, forwards, and downwards, plus 6 mm at the sides, dictates the minimum spacing to adjacent components in the enclosure for proper arc quenching and heat dissipation. The coil connection uses a ring cable lug — factor that into your wiring harness design if your panel standard specifies fork or pin terminals.

With the S00 size and 45 mm width, this contactor occupies one standard DIN-rail module position. Plan for the 10 mm clearance above and below when laying out wire ducts and terminal blocks.

Frequently asked questions

What are the key dimensions of 3RT2016-4AG61?

Width is 45 mm, height is 58 mm, and depth is 73 mm. Clearance requirements are 10 mm upwards, forwards, and downwards, and 6 mm at the sides.

What is the auxiliary contact rating on this contactor?

The auxiliary contact is rated 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.2 A at 440 V, 7.6 A at 480 V, and 2 A at 500 V.

Where can I buy 3RT2016-4AG61 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

Will 3RT2016-4AG61 drop into a panel specified around 3RT2015-1AV02 without rewiring?

Both are S00 frame contactors with the same DIN rail mounting and similar footprint, but the coil voltage and auxiliary contact configuration differ. Verify the coil voltage (24 VDC on this unit) and auxiliary contact ratings against your panel schematic before substituting — a deviation from the customer's approved manufacturer list requires written approval.

MPN
3RT2016-4AG61