Siemens 3RT2017-1AD02 — Contactors

Siemens 3RT2017-1AD02 SIRIUS Power Contactor, Size S00, 24 V

MPN3RT2017-1AD02
Active

Siemens SIRIUS 3RT2017-1AD02 power contactor, size S00, screw-type coil terminals, 24 VDC coil, screw and snap-on mounting on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2017-1AD02 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-1AD02 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-1AD02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz42 V
3RT2017-1AD02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2017-1AD02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-1AD02 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-1AD02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2017-1AD02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-1AD02 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2017-1AD02 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The 45 mm width keeps panel density high.

The contactor is rated for switching frequencies that depend on the duty class: up to 1,000 cycles per hour in AC-1 (resistive loads), 750 in AC-2 and AC-3 (motor starting/running), and 250 in AC-4 (plugging/inching). For most conveyor or pump motor applications running in AC-3, the 750 cycles/hour ceiling is the practical limit — plan your cycle counts against that number. Storage range extends to -55 to +80 °C, relevant if the part sits in an unheated warehouse before commissioning. That means you can orient it to fit tight enclosures without derating, as long as the ambient stays within spec. Wire termination accepts solid or stranded conductors from 0.5 to 4 mm², with dual-wire capability for 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or 2x 4 mm². That covers standard control wiring without needing ferrules, though stranded with ferrules is cleaner for maintenance swaps.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height 58 mm, depth 73 mm. The 45 mm width is standard for a size S00 contactor and matches the footprint of the 3RT2016 frame.

What wire sizes does the screw terminal accept?

Solid or stranded conductors from 0.5 to 4 mm². Dual-wire termination is supported for 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or 2x 4 mm².

Does this contactor have an auxiliary contact block?

Yes, the 3RT2017-1AD02 includes an auxiliary switch. The auxiliary contacts are rated for switching at various voltages: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.2 A at 440 V.

MPN
3RT2017-1AD02