Siemens 3RT2017-1AP02-ZX95 — Contactors

Siemens 3RT2017-1AP02-ZX95 SIRIUS Power Contactor, Size S00,

MPN3RT2017-1AP02-ZX95
Active

Siemens SIRIUS 3RT2017-1AP02-ZX95 power contactor, size S00, 24 V DC coil, screw-type terminals, 45 mm wide, 73 mm depth, 58 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2017-1AP02-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-1AP02-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-1AP02-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2017-1AP02-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2017-1AP02-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-1AP02-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-1AP02-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2017-1AP02-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-1AP02-ZX95 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2017-1AP02-ZX95 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The contactor measures 45 mm wide by 73 mm deep by 58 mm high — a compact footprint that leaves room for auxiliary blocks or overload relays alongside it on the rail.

The electrical switching frequency depends on the duty category: up to 1000 cycles/hour at AC-1 (resistive), 750 cycles/hour at AC-2 or AC-3 (motor starting/running), and 250 cycles/hour at AC-4 (plugging or inching). Wire capacity: accepts solid or stranded conductors from 0.5 to 4 mm², with two conductors per terminal possible for daisy-chaining (2x 0.5…1.5 mm², 2x 0.75…2.5 mm², or 2x 4 mm²). That is standard for a size S00 contactor — no need for special ferrules or oversized lugs.

Clearance and arcing

Keep the side clearance tight at 6 mm; the vertical clearances give room for wiring ducts or auxiliary contact blocks without crowding the arc chamber.

Frequently asked questions

Where can I buy 3RT2017-1AP02-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the depth of 3RT2017-1AP02-ZX95?

The depth is 73 mm, with a width of 45 mm and height of 58 mm.

What wire sizes does this contactor accept?

Solid or stranded conductors from 0.5 to 4 mm², including two-conductor combinations for looping through.

MPN
3RT2017-1AP02-ZX95