Skip to main content
Siemens 3RT2017-1CP04-3MA0 — Contactors

Siemens SIRIUS 3RT2017-1CP04-3MA0 Power Contactor, Size S00,

MPN3RT2017-1CP04-3MA0
Active

Siemens SIRIUS 3RT2017-1CP04-3MA0 power contactor, size S00, 45 mm width, screw-type coil terminals, current production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2017-1CP04-3MA0 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-1CP04-3MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-1CP04-3MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2017-1CP04-3MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2017-1CP04-3MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-1CP04-3MA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-1CP04-3MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2017-1CP04-3MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-1CP04-3MA0 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth117 mm
3RT2017-1CP04-3MA0 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The 3RT2017-1CP04-3MA0: The contactor measures 45 mm wide by 58 mm high by 117 mm deep, fitting the standard S00 footprint that panels already tooled for this size accept without re-drilling or DIN-rail repositioning. It mounts via screw fixing or snap-on onto 35 mm DIN rail per DIN EN 60715, and the mounting position allows ±180° rotation on a vertical surface plus ±22.5° tilt forward and backward — useful when the panel layout forces an unusual orientation.

Switching frequency and duty

Maximum mechanical switching frequency is 10,000,000 operations typical, but the electrical ratings limit throughput by duty: 1,000 cycles/hour at AC-1 (resistive), 750 cycles/hour at AC-2 and AC-3 (motor starting/running), and 250 cycles/hour at AC-4 (plugging/inching). For a conveyor line cycling once per minute, the AC-3 limit of 750/h leaves headroom; for a rapid-reversing application at AC-4, the 250/h ceiling governs the cycle time.

Terminal and wiring

The magnet coil uses screw-type terminals. Main contact wiring accepts solid or stranded conductors from 0.5 to 4 mm², with dual-wire capability for 2×(0.5...1.5 mm²), 2×(0.75...2.5 mm²), or 2×4 mm².

Environmental limits

Frequently asked questions

What are the key dimensions for panel layout?

Width 45 mm, height 58 mm, depth 117 mm. Clearance requirements: 10 mm upward, 10 mm downward, 10 mm forward, and 6 mm at the side.

What conductor sizes does the main contact accept?

Solid or stranded conductors from 0.5 to 4 mm². Dual-wire capability: 2×(0.5...1.5 mm²), 2×(0.75...2.5 mm²), or 2×4 mm².

What is the maximum switching frequency at AC-3 duty?

750 cycles per hour at AC-3 (motor running). At AC-4 (plugging/inching) the limit drops to 250 cycles per hour.

MPN
3RT2017-1CP04-3MA0