Skip to main content
Siemens 3RT2017-1UB41 — Contactors

Siemens 3RT2017-1UB41 SIRIUS Contactor, 24 V DC, Size S00

MPN3RT2017-1UB41
Active

Siemens SIRIUS 3RT2017-1UB41 coupling contactor, size S00, 24 V DC coil, screw-type terminals, 45 mm width, 73 mm depth, 58 mm height.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT2017-1UB41 — Identification
ParameterValue
Contactor frame sizeS00

Ratings & Performance

3RT2017-1UB41 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT2017-1UB41 — Control & Coil
ParameterValue
Control supply voltage typeDC

Contacts & Poles

3RT2017-1UB41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT2017-1UB41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT2017-1UB41 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes

Durability

3RT2017-1UB41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000

Environmental

3RT2017-1UB41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT2017-1UB41 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm

Product details

SIRIUS size S00 — panel density and mounting flexibility

The 3RT2017-1UB41 is a SIRIUS coupling contactor in frame size S00, the smallest in the Siemens contactor family, at 45 mm wide, 58 mm tall, and 73 mm deep. These are the minimum air gaps around the contactor for heat dissipation and arc containment — a panel builder should maintain these to avoid derating or arc flash between adjacent devices.

24 V DC coil and auxiliary contact ratings

The magnet coil is rated 24 V DC with screw-type terminals. This is a coupling contactor — its primary role is to switch control signals or small loads, not main motor power. These ratings define the maximum DC current the contacts can break at each voltage level — important for DC control circuits in industrial panels where inductive loads (relays, solenoids) generate arcs that are harder to extinguish than AC. The contactor includes an auxiliary switch and has a typical mechanical endurance of 30,000,000 cycles — this is the mechanical life before wear-out, not the electrical life under load, which will be lower depending on the switched current and duty class.

Switching frequency and timing for control coordination

These limits are set by the thermal recovery time of the contact tips — exceeding them accelerates contact erosion and can lead to welding. For a safety circuit or sequence interlock, these timing windows matter: the total contactor response from coil energisation to main contact closure is the sum of the operating time plus the arcing time of any preceding device.

Wire termination and environmental limits

This allows daisy-chaining control wiring without additional terminal blocks — common in panel layouts where multiple contactors share a common control signal. The motor rating at 230 V is 2 hp — this is the maximum induction motor load the contactor can switch in AC-3 duty at that voltage.

Frequently asked questions

What is the frame size and mounting of 3RT2017-1UB41?

It is size S00, the smallest SIRIUS contactor frame, measuring 45 mm wide, 58 mm high, and 73 mm deep.

MPN
3RT2017-1UB41