Siemens 3RT2017-2AD02 — Contactors

Siemens 3RT2017-2AD02 SIRIUS Contactor, Size S00, 24 VDC

MPN3RT2017-2AD02
Active

Siemens SIRIUS 3RT2017-2AD02 power contactor, size S00, 24 VDC coil, 45 mm wide, screw and snap-on 35 mm DIN rail mount, spring-type terminal.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2017-2AD02 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-2AD02 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-2AD02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz42 V
3RT2017-2AD02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2017-2AD02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-2AD02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-2AD02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2017-2AD02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-2AD02 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2017-2AD02 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The 24 VDC coil with spring-type terminals means it's a fit for PLC-driven panels where you want fast wiring without screwdriver work — just strip and push. Rated at 10 A for the 24 VDC auxiliary circuit, it handles typical PLC output switching without issue. The contactor switches up to 1 000 cycles per hour in AC-1 duty (resistive loads) and 750 cycles per hour in AC-3 (motor) duty, so it's sized for moderate cycling — conveyor sections, pump starters, fan control.

At 45 mm wide, it takes one standard module slot in the panel. Wire range accepts 0.5 to 4 mm² solid or stranded, or 2x (0.5 to 4 mm²) for looping through. Keep that in mind when laying out the DIN rail — you need those gaps for arc venting and heat dissipation.

Frequently asked questions

Will the 3RT2017-2AD02 drop into a panel specified for the 3RT2017-2AH02-ZX95?

Both are size S00 contactors with the same 45 mm width and DIN rail mounting, so the physical fit and footprint are identical. The difference is the coil voltage — the 2AD02 uses 24 VDC, while the 2AH02-ZX95 uses a different coil. Verify the control voltage before swapping; if your panel runs 24 VDC control, this is a direct mechanical replacement.

What is the depth of the 3RT2017-2AD02?

The depth is 73 mm, with a width of 45 mm and height of 70 mm.

What wire sizes does the 3RT2017-2AD02 accept?

It accepts 0.5 to 4 mm² solid or stranded wire, and 2x (0.5 to 4 mm²) for looping conductors through the terminal.

MPN
3RT2017-2AD02