Siemens 3RT2017-2BE41 — Contactors

Siemens 3RT2017-2BE41 SIRIUS Contactor, Size S00

MPN3RT2017-2BE41
Active

Siemens SIRIUS 3RT2017-2BE41 power contactor, size S00, spring-type coil terminals, 45 mm width, 73 mm depth, screw and snap-on DIN rail mounting.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT2017-2BE41 — Identification
ParameterValue
Contactor frame sizeS00

Ratings & Performance

3RT2017-2BE41 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT2017-2BE41 — Control & Coil
ParameterValue
Control supply voltage typeDC

Contacts & Poles

3RT2017-2BE41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT2017-2BE41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT2017-2BE41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes

Durability

3RT2017-2BE41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000

Environmental

3RT2017-2BE41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT2017-2BE41 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm

Product details

What the frame size and terminal type tell you about fit

The 3RT2017-2BE41: The magnet coil connects via spring-type terminals (cage clamp), not screw terminals — so you need a screwdriver with a small blade to push the spring, not a Pozi driver.

Auxiliary contact ratings — what switches at what voltage

At 400 V AC the auxiliary contact is rated 3 A (cites:,). The DC ratings drop fast as voltage climbs — at 220 V DC you're limited to 0.3 A, so if you're switching a 24 V DC PLC input you're fine at 10 A, but for a 125 V DC control circuit you're down to 0.9 A. That's the contact gap limitation on a size S00 frame (cites:,). At 230 V AC, the contactor is rated for 2 hp motor load — that's the typical small pump or fan motor on a single-phase 230 V supply (cites:).

Switching frequency and operating life by duty class

The AC-4 limit is the one that bites if you're doing reversing or jogging — you get a quarter of the rate of straight starting (cites:,). Electrical life is shorter and depends on the switched current and duty class (cites:).

Environmental limits and clearance

These are minimums for heat dissipation — pack them tighter and you derate the continuous current (cites:,).

Sourced through independent distribution channels against your BOM quantity.

Frequently asked questions

What is the 3RT2017-2BE41's auxiliary contact DC rating at 24 V?

At 48 V DC it drops to 2 A, and at 125 V DC to 0.9 A (cites:,).

MPN
3RT2017-2BE41