Skip to main content
Siemens 3RT2017-2JB41 — Contactors

Siemens 3RT2017-2JB41 SIRIUS Coupling Contactor, 24 VDC Coil

MPN3RT2017-2JB41
Active

Siemens SIRIUS coupling contactor, size S00, 24 VDC coil rated 10 A, spring-type terminals, 45 mm width, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2017-2JB41 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-2JB41 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-2JB41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2017-2JB41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2017-2JB41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-2JB41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-2JB41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT2017-2JB41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-2JB41 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm

Product details

It uses spring-type terminals accepting 0.5 to 4 mm² solid or stranded wire, and mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715.

Duty ratings and switching frequency

Main contact rated current spans 20 A down to 12 A depending on duty. Maximum switching frequency varies by load: 1,000 operations per hour at AC-1 (resistive), 750/h at AC-2 and AC-3 (motor starting/running), and 250/h at AC-4 (plugging/inching). The AC-3e rating also allows 750/h. For a 24 VDC coil, pick-up and drop-out times run 38 to 65 ms, with arcing time of 10 to 15 ms.

The size S00 frame keeps the contactor compact for dense panel layouts.

Frequently asked questions

How do I get current pricing and availability for 3RT2017-2JB41?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.

What is 3RT2017-2JB41's listed depth?

The depth is 73 mm, with a width of 45 mm and height of 70 mm.

What wire sizes does the spring terminal accept?

The spring-type terminals accept 0.5 to 4 mm² solid or stranded wire, and also 2x (0.5 to 4 mm²) for paralleled conductors.

Will 3RT2017-2JB41 drop into a panel specified around 3RT2015-1BW42 without rewiring?

Both are SIRIUS size S00 contactors with the same 45 mm width and DIN rail mounting, so the footprint is identical. However, the 3RT2015-1BW42 uses a different coil voltage and terminal type — verify your coil voltage and wiring method before substituting.

MPN
3RT2017-2JB41