Skip to main content
Siemens 3RT2017-2LF42-0LA0 — Contactors

Siemens SIRIUS 3RT2017-2LF42-0LA0 Power Contactor, 110 V DC

MPN3RT2017-2LF42-0LA0
Active

Siemens SIRIUS power contactor, size S00, 3RT2017-2LF42-0LA0, 110 V DC coil, spring-type terminals, 45 mm width, 11 A at 480/600 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2017-2LF42-0LA0 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-2LF42-0LA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-2LF42-0LA0 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2017-2LF42-0LA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT2017-2LF42-0LA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-2LF42-0LA0 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-2LF42-0LA0 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2017-2LF42-0LA0 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-2LF42-0LA0 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth121 mm

Product details

It switches 11 A at 480 V AC and 600 V AC, and 10 A at 24 V DC — covering both motor and resistive loads in a compact 45 mm wide package that snaps onto a 35 mm DIN rail (DIN EN 60715).

Spring-type terminals accept solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), 2x 4 mm², and solid or stranded 2x (0.5...4 mm²). No screwdriver torque needed — strip, insert, done.

Compared to the 3RT2015-1BW42, the 3RT2017-2LF42-0LA0 steps up from a 24 V DC coil to a 110 V DC coil and adds spring-type terminals instead of screw terminals — a direct swap in the same S00 footprint if your control voltage and termination preference align. No rewiring of the DIN rail or busbar needed.

Mechanical life typical 30,000,000 operations. Arcing time 10...15 ms. Includes an auxiliary switch. Suitable for motor loads up to 2 hp at 230 V AC.

Frequently asked questions

Where can I buy 3RT2017-2LF42-0LA0 and how do I get a price?

It is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the closest functional second-source for 3RT2017-2LF42-0LA0?

The 3RT2015-1BW42 is a size S00 contactor with a 24 V DC coil and screw terminals — same footprint, different coil voltage and termination. The 3RT2017-2LF42-0LA0 uses a 110 V DC coil and spring-type terminals.

What is 3RT2017-2LF42-0LA0's depth?

The depth is 121 mm.

What solid wire sizes does the spring terminal accept?

It accepts 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), 2x 4 mm² solid, and 2x (0.5...4 mm²) solid or stranded.

Will 3RT2017-2LF42-0LA0 drop into a panel specified around 3RT2015-1BW42?

Yes — both are size S00 with the same 45 mm width and DIN-rail mounting. The main difference is the coil voltage (110 V DC vs 24 V DC) and terminal type (spring vs screw). If your control voltage matches, it fits without rewiring the rail.

MPN