Siemens 3RT2018-1AN21 — Contactors

Siemens 3RT2018-1AN21 SIRIUS Power Contactor, Size S00, 45mm

MPN3RT2018-1AN21
Active

Siemens SIRIUS 3RT2018-1AN21 power contactor, Size S00, 45 mm width, screw-type terminals, auxiliary switch, 24 V coil, current production.

$26.67Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2018-1AN21 — Identification
ParameterValue
Contactor frame sizeS00
3RT2018-1AN21 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V11.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2018-1AN21 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz220 V
3RT2018-1AN21 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2018-1AN21 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 25A (690V,100kA), BS88: 50A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2018-1AN21 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2018-1AN21 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2018-1AN21 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2018-1AN21 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2018-1AN21 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The 3RT2018-1AN21: The contactor's coil connection uses screw-type terminals. The main contacts are rated for 20 to 12 operating cycles, with a typical mechanical service life of 30,000,000 operations. Switching frequency varies by duty: up to 1,000 1/h at AC-1, 750 1/h at AC-2, AC-3, and AC-3e, and 250 1/h at AC-4. This means the contactor handles high-cycle resistive loads (AC-1) well, but you must derate significantly for heavy motor jogging or plugging (AC-4).

Wiring and Auxiliary Contact Ratings

Terminals accept solid or stranded conductors from 0.5 to 4 mm², including two conductors per terminal (2x 0.5...1.5 mm², 2x 0.75...2.5 mm², or 2x 4 mm²). This covers most control wiring gauges used in panel building. Auxiliary contact ratings at 24 V rated value is 10 A. At 48 V and 60 V it drops to 2 A, at 110 V to 1 A, at 125 V to 0.9 A, at 220 V to 0.3 A, at 400 V to 3 A, and at 440 V to 0.2 A. The motor rating at 230 V is 2 hp. These are the values to verify against your specific load voltage. Power loss at 50 Hz and 60 Hz is 0.25 each.

Frequently asked questions

What is the depth of the 3RT2018-1AN21?

The depth is 73 mm, which is the dimension to check for enclosure clearance.

What conductor sizes does the 3RT2018-1AN21 accept?

It accepts solid or stranded conductors from 0.5 to 4 mm², including dual-wire terminations up to 2x 4 mm².

Does the 3RT2018-1AN21 include an auxiliary switch?

Yes, it comes with an integrated auxiliary switch.

What is the operating temperature range for this contactor?

The operating temperature range is -25 to +60 °C, with storage from -55 to +80 °C.

MPN
3RT2018-1AN21