Siemens 3RT2018-2AV02 — Contactors

Siemens SIRIUS 3RT2018-2AV02 Power Contactor, Size S00, 24 V

MPN3RT2018-2AV02
Active

Siemens SIRIUS 3RT2018-2AV02, size S00 power contactor, 24 VDC coil, spring-type terminals, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2018-2AV02 — Identification
ParameterValue
Contactor frame sizeS00
3RT2018-2AV02 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V11.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2018-2AV02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz400 V
3RT2018-2AV02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2018-2AV02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 25A (690V,100kA), BS88: 50A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2018-2AV02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2018-2AV02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2018-2AV02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2018-2AV02 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2018-2AV02 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

It mounts on 35 mm DIN rail per DIN EN 60715 via screw or snap-on fastening, and the mounting position allows +/-180° rotation on a vertical surface plus +/-22.5° tilt forward and backward.

AC-4 duty is limited to 250 ops/hr, reflecting the more severe arc wear from reversing or inching. Mechanical life is quoted at 30,000,000 operations typical. Auxiliary switching capacity is given for multiple voltage levels: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.2 A at 440 V. At 230 V the motor rating is 2 hp. These figures define the maximum make/break capability for control circuits at those voltages. The coil connection uses spring-type terminals, and the main contact wiring accepts solid or stranded conductors from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for paralleled feeds. This covers common control and power wiring sizes in European panels.

Integration and spacing

Physical dimensions: width 45 mm, height 70 mm, depth 73 mm. These are the minimum air gaps for heat dissipation and arc containment — account for them when laying out the DIN rail in the enclosure. At 50 Hz and 60 Hz the rated operational current is 0.25 A.

Frequently asked questions

What are the key dimensions and clearances?

Width 45 mm, height 70 mm, depth 73 mm. Minimum clearances: 10 mm upward, 10 mm downward, 10 mm forward, 6 mm at the side.

What wire sizes does the spring terminal accept?

Solid or stranded conductors from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for paralleled runs.

What is the switching frequency for AC-3 duty?

Maximum 750 operations per hour at AC-3; AC-4 is limited to 250 ops/hr.