Siemens 3RT2018-4AN61 SIRIUS Power Contactor, Size S00

MPN3RT2018-4AN61

Siemens SIRIUS 3RT2018-4AN61 power contactor, Size S00, 45 mm width, 73 mm depth, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2018-4AN61 — Identification
ParameterValue
Contactor frame sizeS00
3RT2018-4AN61 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V11.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2018-4AN61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz200 V
3RT2018-4AN61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2018-4AN61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 25A (690V,100kA), BS88: 50A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2018-4AN61 — Connection & Mounting
ParameterValue
Main circuit connectionRing cable lug connection
Aux. / control circuit connectionring terminal lug connection
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2018-4AN61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2018-4AN61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2018-4AN61 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2018-4AN61 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

S00 frame, 45 mm width — panel fit

The 3RT2018-4AN61: This is a Size S00 contactor, 45 mm wide and 73 mm deep, with a height of 58 mm.

Switching capacity across voltages

Rated operational current varies by voltage and duty: at 480 V the contactor switches 14 A; at 400 V it handles 3 A; at 230 V it is rated for 2 hp. The magnet coil connection uses a ring cable lug — confirm the lug ring size against the coil terminal stud before wiring.

Duty-cycle limits and mechanical endurance

Maximum operating cycles per hour: 1,000 in AC-1 (resistive), 750 in AC-3 (motor start/run), and 250 in AC-4 (plugging/inching). The typical mechanical life is 30 million cycles — the electrical life will be lower and depends on the switched load and duty class.

Frequently asked questions

How do I get pricing and availability for 3RT2018-4AN61?

Submit an RFQ with your target quantity.

MPN
3RT2018-4AN61