Siemens 3RT2024-1AN60 — Contactors

Siemens 3RT2024-1AN60 SIRIUS Power Contactor, Size S0, 24 VD

MPN3RT2024-1AN60
Active

Siemens SIRIUS, power contactor, 3RT2024-1AN60, Size S0, 24 VDC coil, screw-type terminals, snap-on DIN rail mounting, auxiliary switch included.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2024-1AN60 — Identification
ParameterValue
Contactor frame sizeS0
3RT2024-1AN60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V12.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2024-1AN60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz200 V
3RT2024-1AN60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2024-1AN60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2024-1AN60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2024-1AN60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2024-1AN60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2024-1AN60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth97 mm
3RT2024-1AN60 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

Switching frequency and duty class — what the numbers mean

The 3RT2024-1AN60 is rated for 1 000 switching cycles per hour under AC-1, AC-2, and AC-3 duty, and 300 cycles per hour under AC-4. AC-3 is the standard motor-switching category (starting and disconnecting a running squirrel-cage motor); AC-4 covers plugging and inching, which stresses the contacts harder. If your application involves frequent reversing or jogging, the AC-4 limit of 300 1/h is the governing number — not the higher AC-3 figure.

Auxiliary contact capacity across voltages

The built-in auxiliary switch breaks 10 A at 24 V rated value, 2 A at 48 V and 60 V, 1 A at 110 V, and 0.3 A at 220 V. At 400 V rated value it handles 3 A. These are the contact ratings for the auxiliary circuit — they define what control loads (PLC inputs, indicator lamps, contactor coils) the auxiliary contacts can switch directly without an interposing relay.

The Size S0 footprint (85 mm height, 45 mm width, 97 mm depth) fits standard 35 mm DIN rail enclosures. Solid or stranded wire accepted: 1... 10 mm² for main contacts, 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²) for the coil and auxiliary circuit.

Frequently asked questions

What is 3RT2024-1AN60's listed depth?

The depth is 97 mm.

What wire sizes does the 3RT2024-1AN60 accept?

Solid or stranded wire: 1... 10 mm² for main contacts. For the coil and auxiliary circuit: 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²).

MPN
3RT2024-1AN60