Siemens 3RT2024-1CL24-3MA0 — Contactors

Siemens 3RT2024-1CL24-3MA0 SIRIUS Power Contactor, S0 Size,

MPN3RT2024-1CL24-3MA0
Active

Siemens SIRIUS power contactor, 3RT2024-1CL24-3MA0, S0 size, 45 mm width, screw-type coil terminals, 35 mm DIN rail snap-on.

$35.56Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2024-1CL24-3MA0 — Identification
ParameterValue
Contactor frame sizeS0
3RT2024-1CL24-3MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V12.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2024-1CL24-3MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2024-1CL24-3MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2024-1CL24-3MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2024-1CL24-3MA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2024-1CL24-3MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2024-1CL24-3MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2024-1CL24-3MA0 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth141 mm
3RT2024-1CL24-3MA0 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

The S0 frame is the bread-and-butter size for this class — fits a 45 mm wide slot on the DIN rail and handles the bulk of 3–7.5 kW motor duty in 400 V plants.

The 60 °C ceiling is standard for a panel-mounted contactor — if your enclosure gets hotter than that from drive heat or solar load, you'll need to derate or move it to a cooler zone. That's a lot of cycles — for a conveyor line cycling once every 10 seconds, that's about 3 years of continuous running before the contacts wear out. The main contact rating is unspecified here, but the S0 frame typically carries 9–12 A in AC-3 duty; the screw-type coil terminals accept solid or stranded wire from 1 to 10 mm², which is the standard range for this frame. No auxiliary switch block is fitted. If your circuit needs feedback contacts for a PLC input or status lamp, you'll need to add a side-mount auxiliary block. The contactor is designed for that — the S0 frame accepts standard SIRIUS auxiliary switch blocks that snap onto the side.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height 85 mm, depth 141 mm. The 45 mm width is the standard S0 frame slot on a DIN rail — it occupies one 45 mm module position.

What wire sizes does the coil terminal accept?

The screw-type coil terminals accept solid or stranded wire from 1 to 10 mm². For fine-stranded wire with ferrules, it also accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²).

Does this contactor include auxiliary contacts?

No auxiliary switch is fitted as standard. You'll need to add a side-mount auxiliary block if your circuit requires feedback contacts.

MPN
3RT2024-1CL24-3MA0