Specifications

3RT2025-1AG20 — Identification
ParameterValue
Contactor frame sizeS0
3RT2025-1AG20 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2025-1AG20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz110 V
3RT2025-1AG20 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2025-1AG20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2025-1AG20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2025-1AG20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2025-1AG20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2025-1AG20 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth97 mm
3RT2025-1AG20 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

Current lifecycle — active production

The 3RT2025-1AG20: This is a SIRIUS-branded power contactor, size S0, designed for screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715 — the standard panel footprint for European control cabinets.

Panel fit and wiring constraints

The contactor measures 45 mm wide by 85 mm high by 97 mm deep — the 45 mm width is the S0 frame standard, occupying one 45 mm DIN-rail module. The 97 mm depth includes the coil terminals and arc chamber; verify clearance behind the panel door for the arcing space (10 mm forwards, 10 mm upwards, 10 mm downwards, 6 mm at the side). Main contact wiring accepts solid or stranded conductors from 1 to 10 mm². Auxiliary contact wiring accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) — the dual-wire entry is useful for daisy-chaining control signals without a separate terminal block.

Switching duty and thermal limits

Rated for 1,000 operating cycles per hour in AC-1, AC-2, AC-3, and AC-3e duty, dropping to 300 cycles per hour in AC-4 (plugging/inching) — the AC-4 limit reflects the higher thermal stress of reversing or jogging loads. The arcing time is 10 to 10 ms, consistent with a contactor designed for fast arc extinction in a compact frame. Ambient operating range is -25 to +60 °C during operation, with storage from -55 to +80 °C. The 60 °C ceiling is standard for panel-mounted contactors; above 55 °C the continuous current rating may need derating per IEC 60947-4-1.

Auxiliary contact ratings across voltages

The built-in auxiliary switch is rated 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 0.6 A at 440 V — these are the make/break capacities for the control circuit, not the main contact rating. At 230 V the contactor is rated 3 hp for motor starting.

Frequently asked questions

What is 3RT2025-1AG20's listed depth (97 mm) on this component line?

The depth is 97 mm, measured from the DIN rail mounting surface to the front of the coil terminals. This is the S0 frame depth; panel clearance of at least 10 mm forwards is required for arcing.