Skip to main content
Siemens 3RT2026-1AL20-ZX95 — Contactors

Siemens 3RT2026-1AL20-ZX95 SIRIUS Power Contactor, S0 Size,

MPN3RT2026-1AL20-ZX95
Active

Siemens SIRIUS power contactor, 3RT2026-1AL20-ZX95, S0 size, 45 mm width, screw-type terminals, auxiliary switch included, active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2026-1AL20-ZX95 — Identification
ParameterValue
Contactor frame sizeS0
3RT2026-1AL20-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2026-1AL20-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2026-1AL20-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2026-1AL20-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2026-1AL20-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2026-1AL20-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2026-1AL20-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2026-1AL20-ZX95 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth97 mm
3RT2026-1AL20-ZX95 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, and the mounting position allows +/-180° rotation on a vertical surface plus +/-22.5° tilt forward/backward. That flexibility means it fits into tight panel layouts without forcing a specific orientation.

Wire range accepts solid or stranded conductors from 1 to 10 mm², and for double ferruled connections it handles 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²). That covers most control and power wiring you'll see in a standard industrial panel — no need for special lugs or adapters.

Switching frequency and thermal limits

Maximum switching rates are 1,000 cycles per hour for AC-1 resistive loads, 750 cycles per hour for AC-3 motor starting, and 250 cycles per hour for AC-4 inching/plugging duty. The arcing time is 10 ms, and the coil operates on AC with pick-up times of 4 to 16 ms. For a line-down replacement, these numbers tell you the contactor can keep up with a fast cycling process without overheating the coil or welding the contacts.

Frequently asked questions

What wire sizes does it accept?

Solid or stranded 1 to 10 mm² for single conductors, and 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) for double ferruled connections.

How does it mount?

Screw or snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Mounting position allows +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward.

MPN