Siemens 3RT2026-1BD40 — Contactors

Siemens SIRIUS 3RT2026-1BD40 Power Contactor, Size S0, 42 V

MPN3RT2026-1BD40
Active

Siemens SIRIUS 3RT2026-1BD40 power contactor, Size S0, 42 V 50/60 Hz coil, screw terminals, 3 hp at 230 V, 10 A at 24 V DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2026-1BD40 — Identification
ParameterValue
Contactor frame sizeS0
3RT2026-1BD40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2026-1BD40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2026-1BD40 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2026-1BD40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2026-1BD40 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2026-1BD40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2026-1BD40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2026-1BD40 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth107 mm

Product details

The coil holds at 42 V nominal; the operating range spans 0.8 to 1.1 times the rated value. Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, and the mounting position allows +/-180° rotation on a vertical surface plus +/-22.5° tilt forward and backward — enough flexibility to fit tight enclosures without derating.

Switching Capacity and Duty Ratings

For motor starting (AC-3 duty), the contactor is rated for 3 hp at 230 V — that's the headline number for a 3-phase motor on a 230 V line. At 400 V, the AC-3 rating is 3 A, so it handles smaller motors at higher line voltages. DC switching is specified per voltage step: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, and 0.3 A at 220 V. These are resistive-load ratings (AC-1 equivalent); inductive DC loads need derating or arc-suppression across the contacts. Mechanical switching frequency limits vary by duty: 1 000 cycles/hour for AC-1 (resistive), 750 cycles/hour for AC-2 and AC-3 (motor start/run), and 250 cycles/hour for AC-4 (plugging/inching). The arcing time sits at 10 ms, typical for a Size S0 contactor.

The closest functional peer is the 3RT2026-1FB44-3MA0, which carries a different coil voltage but shares the same Size S0 frame and screw-terminal layout.

Integration and Clearance

Dimensions: 85 mm height, 45 mm width, 107 mm depth. These are for ventilation and arc-quenching — stacking contactors closer than that requires thermal derating. Wire range: solid or stranded 1 to 10 mm² for the main power circuit, and 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) for auxiliary/control wiring. Screw terminals are standard; torque values follow the manufacturer's tightening spec on the terminal face.

Environmental and Mechanical Life

The storage limit governs handling during shipping and off-season storage, not running conditions. Electrical life depends on switching current and duty cycle; for AC-3 at rated current, expect roughly 1 to 2 million operations. An auxiliary switch is built into the contactor (yes/no flag indicates yes), so no separate add-on block is needed for basic status feedback to the PLC or indicator lamp.

Frequently asked questions

What wire sizes does the 3RT2026-1BD40 accept?

Solid or stranded wire from 1 to 10 mm² for the main power circuit. For auxiliary/control wiring, it accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²). Terminals are screw-type.

Will the 3RT2026-1BD40 drop into a panel specified around the 3RT2026-1FB44-3MA0 without rewiring?

Yes, mechanically and electrically for the power circuit. Both are Size S0 with screw terminals and identical mounting footprint. The only change is the coil voltage — the -1BD40 uses a 42 V coil, so the control transformer tap or supply must match.

MPN
3RT2026-1BD40