Specifications

3RT2026-2AK64-3MA0 — Identification
ParameterValue
Contactor frame sizeS0
3RT2026-2AK64-3MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2026-2AK64-3MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz110 V
3RT2026-2AK64-3MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2026-2AK64-3MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2026-2AK64-3MA0 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2026-2AK64-3MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2026-2AK64-3MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2026-2AK64-3MA0 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth144 mm
3RT2026-2AK64-3MA0 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

Rated for AC-3 duty at 750 operating cycles per hour maximum, this contactor handles the frequent start-stop demands of conveyor and pump applications. For resistive loads (AC-1), it can cycle up to 1000 times per hour. The coil draws 0.25 A at 50 Hz and 0.28 A at 60 Hz, a narrow spread that keeps the control transformer sizing consistent regardless of line frequency.

Wire range accepts solid or stranded conductors from 1 to 10 mm² for the main circuit, and 2x (0.5 to 2.5 mm²) for finer control wiring. The spring-type terminals on the coil eliminate the risk of loose screw connections under vibration — relevant for machines with frequent cycling.

Frequently asked questions

What are the key ratings for 3RT2026-2AK64-3MA0?

It is an S0-size power contactor rated for AC-3 duty at 750 operating cycles per hour maximum, with spring-type terminals, 45 mm width, and a 144 mm depth. The coil draws 0.25 A at 50 Hz and 0.28 A at 60 Hz.

Where can I buy 3RT2026-2AK64-3MA0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

How does 3RT2026-2AK64-3MA0 compare to 3RT2015-2AP02?

The 3RT2015-2AP02 is a smaller frame size (S00 vs S0) with a lower current rating and screw terminals. The 3RT2026-2AK64-3MA0 offers higher switching capacity and spring-type coil terminals, but both share the same DIN rail mounting pattern and SIRIUS accessory ecosystem. Panel re-wiring is required when swapping between the two due to different terminal arrangements and frame dimensions.

MPN
3RT2026-2AK64-3MA0