Specifications

3RT2026-2BB44-ZX95 — Identification
ParameterValue
Contactor frame sizeS0
3RT2026-2BB44-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2026-2BB44-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2026-2BB44-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2026-2BB44-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2026-2BB44-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2026-2BB44-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2026-2BB44-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2026-2BB44-ZX95 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth154 mm

Product details

What It Is & What It Does

The 24 VDC coil pulls in at 0.8 of rated voltage and drops out at 1.1 of rated voltage — standard pickup/dropout margins for this class.

Rated operational current is 6 A at 24 V — that's the continuous current the main contacts carry at that coil voltage. For motor duty (AC-3), it's rated for 750 switching cycles per hour maximum; for resistive loads (AC-1), up to 1000 cycles per hour. The arcing time is a tight 10 ms, which limits contact erosion during break.

Mounting & Clearances

That 6 mm side gap is tight — factor it into your DIN rail layout if you're stacking multiple contactors.

Terminal Capacity & Mechanical Life

For the coil terminals, use 2x (0.5 to 2.5 mm²) solid or stranded.

Environmental Range

The storage range is wider than the operating range — that's typical for handling and warehousing, not for running the coil at those extremes.

Frequently asked questions

What are the key dimensions of this contactor?

Width is 45 mm, height is 102 mm, depth is 154 mm. That depth includes the spring-type terminal protrusion — account for it when sizing your enclosure depth.

What wire sizes does the 3RT2026-2BB44-ZX95 accept?

Main contacts accept 1 to 10 mm² solid or stranded. Coil terminals accept 2x (0.5 to 2.5 mm²) solid or stranded. Spring-type terminals on the coil — no screw torque needed.

How does this compare to the 3RT2026-1FB44-3MA0?

The 3RT2026-1FB44-3MA0 is a sibling in the same S0 frame size, but it uses screw-type terminals on the main contacts rather than spring-type. If your panel is already wired for screw terminals, the 1FB44 variant drops in without retooling your lugging process. The 2BB44's spring terminals save wiring time but require a ferrule for stranded wire below 1 mm².

MPN