Skip to main content
Siemens 3RT2026-2CK64-3MA0 — Contactors

Siemens SIRIUS 3RT2026-2CK64-3MA0 Power Contactor, Size S0,

MPN3RT2026-2CK64-3MA0
Active

Siemens SIRIUS power contactor, size S0, 3RT2026-2CK64-3MA0, 45 mm width, spring-type terminals, screw and snap-on mounting onto 35 mm DIN rail per EN 60715.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2026-2CK64-3MA0 — Identification
ParameterValue
Contactor frame sizeS0
3RT2026-2CK64-3MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2026-2CK64-3MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz110 V
3RT2026-2CK64-3MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2026-2CK64-3MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2026-2CK64-3MA0 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2026-2CK64-3MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2026-2CK64-3MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2026-2CK64-3MA0 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth144 mm
3RT2026-2CK64-3MA0 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

The 3RT2026-2CK64-3MA0 is a Siemens SIRIUS power contactor in the size S0 frame, 45 mm wide, designed for screw and snap-on mounting onto 35 mm standard mounting rail per DIN EN 60715. The main contacts accept solid or stranded conductors from 1 to 10 mm², and the spring-type coil terminals accept dual conductors 2x (0.5 to 2.5 mm²). No auxiliary switch is fitted on this variant, so any auxiliary contact block must be ordered separately and added to the front or side of the contactor.

Duty Cycle and Switching Ratings

This contactor is rated for motor switching up to 3 hp at 230 V (per). For resistive loads (AC-1), the maximum switching rate is 1,000 operations per hour; for motor loads under AC-3 or AC-3e duty, the maximum is 750 ops/h. For the most demanding AC-4 duty (plugging, inching), the rate drops to 250 ops/h. The typical mechanical life is 10,000,000 operations, so the contactor is designed for high-cycle applications when operated within these limits. Switching current ratings are specified per voltage: 6 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.6 A at 440 V. The arcing time at AC is 4 to 16 ms. Coil holding power is 0.25 VA at 50 Hz and 0.28 VA at 60 Hz.

Environmental and Lifecycle Status

The 3RT2026-2CK64-3MA0 is in the current lifecycle stage per the manufacturer. For audit purposes, the datasheet and compliance documentation (RoHS, REACH, relevant IEC/UL standards) are available from the manufacturer upon request — this part is a standard catalog item, not a special or phased-out variant.

Frequently asked questions

Where can I buy 3RT2026-2CK64-3MA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is 3RT2026-2CK64-3MA0's listed depth on this component line?

The depth is 144 mm. Combined with the 45 mm width and 102 mm height, this defines the panel footprint for DIN rail layout.

What compliance documentation does this brand provide for 3RT2026-2CK64-3MA0?

As a Siemens SIRIUS catalog item, the manufacturer provides RoHS and REACH declarations, and the part is designed to relevant IEC and UL standards. Specific certificates are available from Siemens upon request.

Will 3RT2026-2CK64-3MA0 drop into a panel specified around 3RT2024-1AL20-ZX95 without rewiring?

Both are size S0 Siemens SIRIUS contactors with the same 45 mm width and DIN rail mounting, so the mechanical footprint is identical. However, the terminal types and auxiliary configurations may differ — verify the coil voltage and auxiliary contact arrangement against your panel wiring before substitution.

MPN
3RT2026-2CK64-3MA0