Skip to main content
Siemens 3RT2026-2DM40 — Contactors

Siemens 3RT2026-2DM40 SIRIUS Power Contactor, S0 Frame, Spri

MPN3RT2026-2DM40
Active

Siemens SIRIUS power contactor, size S0, 3RT2026-2DM40, spring-type terminals, 3-pole, 107 mm depth, 45 mm width, 102 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2026-2DM40 — Identification
ParameterValue
Contactor frame sizeS0
3RT2026-2DM40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2026-2DM40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2026-2DM40 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2026-2DM40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 100 A (690 V, 100 kA), aM: 50 A (690 V, 100 kA), BS88: 100 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 35A (690V, 100kA), aM: 20A (690V, 100kA), BS88: 35A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2026-2DM40 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2026-2DM40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2026-2DM40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2026-2DM40 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth107 mm

Product details

Siemens 3RT2026-2DM40 — SIRIUS Power Contactor, S0 Frame

The contactor sits at 107 mm deep, 45 mm wide, 102 mm tall — standard S0 footprint that drops into existing panels without re-drilling.

Switching Duty & What the Ratings Mean

Switching frequency tells you the mechanical pace this contactor can sustain in a given duty class. At AC-3 (squirrel-cage motor starting) it's rated 750 operations per hour maximum; at AC-4 (inching/plugging) that drops to 250 1/h because the arc energy per cycle is higher. AC-1 resistive loads let it run at 1 000 1/h. For DC switching, the contactor carries 10 A at 24 V rated value, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V — these are the current limits per pole for DC-1/DC-3 style loads. The 3 hp rating at 230 V lines up with a typical small motor application.

The spring-type terminals accept solid or stranded wire from 1 to 10 mm², or two conductors of 0.5 to 2.5 mm² each.

Frequently asked questions

How do I get current pricing and availability for 3RT2026-2DM40?

Submit an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network. No stock count or price is published here.

Will 3RT2026-2DM40 drop into a panel specified around 3RT2015-1BW42 without rewiring?

Yes, both are S0 frame contactors with the same 45 mm width, 107 mm depth, and 35 mm DIN-rail mounting. The 3RT2026-2DM40 uses spring-type terminals instead of screw terminals, but the wire range (1–10 mm² solid/stranded) and pole count match, so no panel rework is needed.

What is 3RT2026-2DM40's listed depth?

107 mm. Combined with a 45 mm width and 102 mm height, it occupies the standard S0 contactor envelope.

What wire sizes does the spring terminal accept?

Solid or stranded wire from 1 to 10 mm², or two conductors of 0.5 to 2.5 mm² each. The spring-type terminals are on both the main contacts and the coil.

MPN
3RT2026-2DM40