3RT2027-1AK64-3MA0
power contactor, AC-3e/AC-3, 32 A, 15 kW / 400 V, 3-pole, 110 V AC, 50 Hz / 120 V, 60 Hz, auxiliary contacts: 2 NO + 2 NC, screw terminal, size: S0, captive auxiliary switch
Specifications
| Parameter | Value |
|---|---|
| Contactor frame size | S0 |
| Parameter | Value |
|---|---|
| Rated operational current, AC-12, max. | 10 A |
| Rated operational current, AC-4 @ 400 V | 22 A |
| Rated value @ 400 V | 3 A |
| Rated value @ 500 V | 2 A |
| Rated value @ 690 V | 1 A |
| Rated value @ 230 V | 5 hp |
| Rated value @ 24 V | 6 A |
| Rated value @ 60 V | 2 A |
| Rated value @ 110 V | 1 A |
| Rated value @ 220 V | 0.3 A |
| Parameter | Value |
|---|---|
| Control supply voltage type | AC |
| Rated value @ 50 Hz | 0.25 |
| Rated value @ 50 Hz | 110 V |
| Parameter | Value |
|---|---|
| Main poles | 3 |
| Main NO contacts | 3 |
| Auxiliary contact reliability | 1 faulty switching per 100 million (17 V, 1 mA) |
| Parameter | Value |
|---|---|
| Short-circuit coordination type 1, fuse | gG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA) |
| Short-circuit coordination type 2, fuse | gG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA) |
| Aux. switch short-circuit protection, fuse | gG: 10 A (500 V, 1 kA) |
| Parameter | Value |
|---|---|
| Main circuit connection | screw-type terminals |
| Aux. / control circuit connection | screw-type terminals |
| Conductor cross-section, solid | 1 ... 10 mm² |
| Conductor cross-section, solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Conductor cross-section, finely stranded w/ ferrule | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Mounting method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| Side-by-side mounting | Yes |
| Parameter | Value |
|---|---|
| Durability (operating cycles, typ.) | 10 000 000 |
| Durability with aux. switch block (cycles, typ.) | 10 000 000 |
| Parameter | Value |
|---|---|
| Operating temperature range | -25 ... +60 °C |
| Storage temperature range | -55 ... +80 °C |
| Installation altitude, max. | 2 000 m |
| Parameter | Value |
|---|---|
| Width | 45 mm |
| Height | 85 mm |
| Depth | 141 mm |
| Parameter | Value |
|---|---|
| At AC | 4 ... 16 ms |
Frequently asked questions
What is the coil voltage of the Siemens 3RT2027-1AK64-3MA0?
Buyers must confirm the 110 V AC 50 Hz / 120 V AC 60 Hz coil matches their control circuit before purchase.
What size AC motor can the 3RT2027-1AK64-3MA0 control at 400 V?
Verifies the 15 kW / 32 A AC-3e rating is suitable for the intended motor load.
How does the 3RT2027-1AK64-3MA0 differ from a standard 3RT2027 contactor?
Clarifies the captive auxiliary switch and 2 NO + 2 NC configuration vs. base 3RT2027 variants.
How many auxiliary contacts does the 3RT2027-1AK64-3MA0 have?
Confirms 2 NO + 2 NC configuration for control wiring and interlocking design.
Is the Siemens 3RT2027-1AK64-3MA0 still an active product?
Active status determines long-term spares availability and avoids obsolescence risk.
Where can I buy a genuine 3RT2027-1AK64-3MA0 with current stock?
Identifies authorized Siemens distributors to mitigate counterfeit risk on premium components.