Siemens 3RT2027-2AH00 — Contactors

Siemens 3RT2027-2AH00 SIRIUS Power Contactor, S0 Frame, 480V

MPN3RT2027-2AH00
Active

Siemens SIRIUS S0 power contactor, 3RT2027-2AH00, spring-type terminals, 27 A at 480 V AC-3, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2027-2AH00 — Identification
ParameterValue
Contactor frame sizeS0
3RT2027-2AH00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V22 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V5 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2027-2AH00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz48 V
3RT2027-2AH00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2027-2AH00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)
Short-circuit coordination type 2, fusegG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2027-2AH00 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2027-2AH00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2027-2AH00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2027-2AH00 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth97 mm
3RT2027-2AH00 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

The S0 frame measures 45 mm wide by 102 mm high by 97 mm deep — that depth keeps it clear of most 80 mm-deep enclosure backplates, but verify clearance if you're mounting it behind a door with a shallow gland plate. Solid or stranded wire from 1 to 10 mm² fits the main contact terminals; the auxiliary contact terminals accept 2x 0.5 to 2.5 mm². Spring-clamp termination means no screw torque to check, but strip length needs to be precise — 8 mm is typical for this class.

Frequently asked questions

What is 3RT2027-2AH00's listed depth?

The depth is 97 mm. That's the body depth excluding any protruding terminals or arc chambers.

What wire sizes does 3RT2027-2AH00 accept on the main contacts?

Solid or stranded wire from 1 to 10 mm². The auxiliary contacts accept 2x 0.5 to 2.5 mm².

Will 3RT2027-2AH00 drop into a panel specified around 3RT2036-1AC20-ZX95 without rewiring?

Both are SIRIUS S0-frame contactors, so the footprint and DIN rail mounting are identical. The 3RT2027-2AH00 uses spring-type terminals while the 3RT2036-1AC20-ZX95 may use screw terminals — if the panel was wired for screw terminals, the spring-clamp version will still accept the same wire sizes (1 to 10 mm² solid or stranded), so no rewiring is needed at the terminal level. Verify the auxiliary contact configuration matches your control circuit.

MPN