Skip to main content
Siemens 3RT2027-2XG40-0LA2 — Contactors

Siemens 3RT2027-2XG40-0LA2 SIRIUS Contactor, 24 VDC Coil, S0

MPN3RT2027-2XG40-0LA2
Active

Siemens SIRIUS contactor 3RT2027-2XG40-0LA2, S0 frame, 24 VDC coil, spring-type terminals, 45 mm wide, 107 mm deep.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2027-2XG40-0LA2 — Identification
ParameterValue
Contactor frame sizeS0
3RT2027-2XG40-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V22 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V5 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2027-2XG40-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2027-2XG40-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT2027-2XG40-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)
Short-circuit coordination type 2, fusegG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2027-2XG40-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (1 ... 10 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2027-2XG40-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2027-2XG40-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2027-2XG40-0LA2 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth107 mm

Product details

The Siemens SIRIUS 3RT2027-2XG40-0LA2 is a size S0 contactor with a 24 VDC coil and spring-type terminals on the magnet coil, rated for 10 A at 24 VDC and 5 hp at 230 VAC. It mounts on a 35 mm DIN rail per EN 60715 via screw or snap-on, and fits a 45 mm wide, 102 mm high, 107 mm deep footprint. The DC coil drops out with a 30 to 50 ms delay, arcing time is 10 ms.

Compared to the 3RT2326-1BK80 (a larger-frame contactor with higher current ratings and different coil voltage), the 3RT2027-2XG40-0LA2 is a compact S0 unit with a 24 VDC coil. The 3RT2326-1BK80 will not drop into the same DIN-rail footprint or panel cutout without re-spacing; the 3RT2027-2XG40-0LA2 is the correct size for S0-based designs.

Spring-type terminals on the coil accept 2x (0.5 to 2.5 mm²) stranded or 2x (1 to 10 mm²) solid wire. The main contact terminals follow the same range (1 to 10 mm² solid). The auxiliary switch is integrated. For DC switching, the contactor is rated for 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. Maximum operating frequency: 750 operations per hour for AC-1, AC-2, AC-3, and AC-3e; 250 ops/h for AC-4.

Frequently asked questions

Who supplies 3RT2027-2XG40-0LA2 and how is it quoted for volume purchases?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for volume pricing.

What is the depth of 3RT2027-2XG40-0LA2?

The listed depth is 107 mm.

What solid wire size does the 3RT2027-2XG40-0LA2 accept?

The terminals accept 2x (1 to 10 mm²) solid wire.

Will 3RT2027-2XG40-0LA2 drop into a panel specified around 3RT2326-1BK80 without rewiring?

No — the 3RT2326-1BK80 is a larger frame size with different mounting footprint and coil voltage. The 3RT2027-2XG40-0LA2 is an S0-size contactor; you would need to re-space the DIN rail and verify the coil supply (24 VDC).

MPN
3RT2027-2XG40-0LA2