Siemens 3RT2028-1AP04-ZX95 SIRIUS Power Contactor

MPN3RT2028-1AP04-ZX95
Active

Siemens SIRIUS 3RT2028-1AP04-ZX95 power contactor, size S0, 3-pole, 34 A at 480 V AC-3, 45 mm width, 141 mm depth, screw and snap-on mounting onto 35 mm DIN rail per EN 60715.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT2028-1AP04-ZX95 — Identification
ParameterValue
Contactor frame sizeS0

Ratings & Performance

3RT2028-1AP04-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V22 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V5 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT2028-1AP04-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V

Contacts & Poles

3RT2028-1AP04-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT2028-1AP04-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)
Short-circuit coordination type 2, fusegG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT2028-1AP04-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes

Durability

3RT2028-1AP04-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000

Environmental

3RT2028-1AP04-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT2028-1AP04-ZX95 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth141 mm

Specifications

3RT2028-1AP04-ZX95 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

Panel Fit and Mounting Constraints

The 3RT2028-1AP04-ZX95 is a size S0 power contactor with a width of 45 mm and a depth of 141 mm — the depth is the dimension that dictates enclosure selection, especially in shallow backpanels or retrofit cabinets where gland-plate clearance is tight. Mounting is via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, with the mounting position allowing +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward, so it can be oriented to fit cable entry paths without violating the clearance zones. Minimum air and creepage clearances are specified: 10 mm upwards, 10 mm forwards, 10 mm downwards, and 6 mm at the side — these must be maintained to the enclosure wall or adjacent components to avoid arc flash or tracking under fault.

Rated Motor Current and Duty Cycles

Rated at 34 A at 480 V in AC-3 duty (the standard motor-switching category for squirrel-cage motors), this contactor handles typical North American 480 V three-phase motor loads up to that current — which corresponds to roughly a 20–25 hp motor depending on full-load amps. Maximum switching frequency varies by duty: 1000 operations per hour in AC-1 (resistive), 750/h in AC-2 and AC-3, and 250/h in AC-4 (plugging/inching) — so for high-cycle applications like conveyor indexing or compressor cycling, stay within the AC-3 ceiling of 750 ops/h to avoid contact wear. The contactor's mechanical life is rated at 10 million operations typical, with an arcing time of 10 ms at 50 Hz — this is the contact separation interval during which the arc extinguishes; the 4–16 ms AC arcing window covers variations in load power factor and supply voltage.

Wire Termination and Auxiliary Contact Provisions

Main contact terminations accept solid or stranded wire from 1 to 10 mm² (roughly 18 to 8 AWG), and the magnet coil uses screw-type terminals — no special crimp tooling is required for field wiring, but torque settings should follow the Siemens installation instructions to avoid terminal damage. Auxiliary switch blocks are not included as standard (the base contactor has no auxiliary contacts), so if the application requires feedback or interlocking, a separate auxiliary contact block must be ordered and snapped onto the contactor's side or front — the S0 frame supports Siemens auxiliary switch modules.

Frequently asked questions

What is the rated motor current for 3RT2028-1AP04-ZX95 at 480 V?

It is rated 34 A at 480 V in AC-3 duty, which is the standard category for switching squirrel-cage induction motors. This corresponds to a motor size of roughly 20–25 hp at 480 V, depending on the motor's full-load current.