Siemens 3RT2028-2AP00-ZX95 — Contactors

Siemens 3RT2028-2AP00-ZX95 SIRIUS Power Contactor, 34 A AC-3

MPN3RT2028-2AP00-ZX95
Active

Siemens SIRIUS 3RT2028-2AP00-ZX95 power contactor, size S0, 34 A AC-3 at 480 V, spring-type coil terminals, screw and snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2028-2AP00-ZX95 — Identification
ParameterValue
Contactor frame sizeS0
3RT2028-2AP00-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V22 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V5 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2028-2AP00-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2028-2AP00-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2028-2AP00-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)
Short-circuit coordination type 2, fusegG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2028-2AP00-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2028-2AP00-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2028-2AP00-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2028-2AP00-ZX95 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth97 mm
3RT2028-2AP00-ZX95 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

Its headline motor rating is 34 A in AC-3 duty at 480 V — that's the current it can make and break under full-load motor starting conditions, so it handles a 3-phase induction motor up to that line current without welding the contacts or overheating the arc chamber. At 230 V it carries a 5 hp motor load. The coil termination uses spring-type terminals, not screw clamps, which speeds panel wiring and resists loosening under vibration. The main and auxiliary wiring accepts solid or stranded conductors from 1 to 10 mm², and can take two conductors of 0.5 to 2.5 mm² in a single clamp.

The S0 frame is 45 mm wide, 102 mm tall, 97 mm deep — fits a standard 45 mm slot on the rail. Clearance: 10 mm above, below, and forward; 6 mm to the side.

Switching performance and endurance

Rated for up to 1,000 switching cycles per hour in AC-1 resistive duty, 750 cycles/h in AC-2 and AC-3 motor duty, and 250 cycles/h in the severe AC-4 plugging/reversing duty. Arcing time at AC is 4 to 16 ms.

Environmental and auxiliary ratings

The auxiliary switch is present and rated for switching at various control voltages: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.6 A at 440 V. Coil holding power at 50 Hz is 0.25 W.

Frequently asked questions

What is the closest functional second-source — 3RT2028-1AU00?

The 3RT2028-1AU00 is a peer in the same SIRIUS S0 family, but it uses screw-type coil terminals instead of the spring-type terminals on the 2AP00. Both share the same frame size and mounting footprint, so a panel laid out for the 1AU00 can accept the 2AP00 without rewiring the main power or control wiring — the coil termination method is the only difference that affects the control circuit connection.

What is the listed depth?

97 mm.

What wire cross-section does it accept?

Solid or stranded conductors from 1 to 10 mm² for single wires, or two conductors of 0.5 to 2.5 mm² in one clamp.

Will it drop into a panel specified around 3RT2028-1AU00 without rewiring?

Yes — same S0 frame, same 45 mm width, same DIN rail mounting and clearance requirements. The only difference is the coil terminal type: spring-clamp on the 2AP00 versus screw on the 1AU00. If the panel already has ring-tongue or fork terminals for the coil, you will need to strip and insert the wire into the spring cage instead.

MPN
3RT2028-2AP00-ZX95