Siemens 3RT2036-3AF06 SIRIUS Power Contactor, Size S2, 52 A

MPN3RT2036-3AF06
Active

Siemens SIRIUS power contactor, 3RT2036-3AF06, Size S2, rated 52 A at 480 V, screw and snap-on 35 mm DIN rail mounting, spring-type coil terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2036-3AF06 — Identification
ParameterValue
Contactor frame sizeS2
3RT2036-3AF06 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2036-3AF06 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.37
Rated value @ 50 Hz110 V
3RT2036-3AF06 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2036-3AF06 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2036-3AF06 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2036-3AF06 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2036-3AF06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2036-3AF06 — Mechanical
ParameterValue
Width75 mm
Height114 mm
Depth130 mm
3RT2036-3AF06 — Specifications
ParameterValue
At AC10 ... 18 ms

Product details

The Siemens 3RT2036-3AF06 is a SIRIUS Size S2 power contactor rated 52 A at 480 V, making it a fit for switching motor loads up to that current in AC-3 duty. It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, with a ±180° rotation range on vertical surfaces and ±22.5° tilt allowance — useful when panel layout forces an unconventional orientation. The coil connection uses spring-type terminals, so no screwdriver is needed for the control wiring — just strip and push. Main contacts are configured as 18 normally-open, 1 normally-closed (18 NO / 1 NC), which covers most three-phase motor circuits with an auxiliary NC for interlocking or status feedback.

Duty-cycle and switching frequency limits

Maximum switching frequency depends on the duty class: 1,000 cycles/hour in AC-1 (resistive), 800 in AC-3 and AC-3e (motor starting/running), 600 in AC-2 (slip-ring motor), and 250 in AC-4 (plugging/inching). If your application cycles faster than these limits, you'll need to step up to a larger frame or reduce the load current.

Environmental and mounting clearances

These matter for heat dissipation and arc-flash containment — don't crowd it against other components. Dimensions are 114 mm high, 75 mm wide, 130 mm deep. The 75 mm width is three 25 mm module spaces on a DIN rail, so it occupies three standard positions.

Auxiliary contact ratings across voltages

The auxiliary contacts (no auxiliary switch block included as standard — this is the base contactor) are rated for the following currents at various control voltages: 6 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.6 A at 440 V, and 2 A at 500 V. These are the make/break capacities for the built-in auxiliary circuit; if you need more auxiliary contacts, add a separate auxiliary switch block.

Frequently asked questions

Where can I buy 3RT2036-3AF06 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

What is 3RT2036-3AF06's depth and width?

Depth is 130 mm and width is 75 mm (three 25 mm DIN rail module spaces).

Will 3RT2036-3AF06 drop into a panel built for 3RT2037-1AL20-ZX95?

Both are SIRIUS Size S2 contactors on the same 35 mm DIN rail footprint, so the mounting and main power connections are interchangeable. However, the 3RT2036-3AF06 is rated 52 A at 480 V while the 3RT2037-1AL20-ZX95 is a higher-current variant — verify your load current before swapping. The coil terminal type and auxiliary contact configuration may also differ.

What compliance documentation does Siemens provide for 3RT2036-3AF06?

As a standard SIRIUS industrial control product, it carries CE marking for the European market and is designed to meet relevant IEC and EN standards. Specific declarations (RoHS, REACH, UL) are available from Siemens upon request or via their support portal — the evidence does not list individual cert numbers here.