Siemens 3RT2036-3SP30 — Contactors

Siemens 3RT2036-3SP30 SIRIUS Power Contactor, Size S2, 175-2

MPN3RT2036-3SP30
Active

Siemens SIRIUS power contactor, 3RT2036-3SP30, Size S2, coil rated 175-280 VAC, spring-type terminals, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2036-3SP30 — Identification
ParameterValue
Contactor frame sizeS2
3RT2036-3SP30 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2036-3SP30 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz2 VA
Rated value @ 50 Hz175 ... 280 V
3RT2036-3SP30 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2036-3SP30 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2036-3SP30 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2036-3SP30 — Durability
ParameterValue
Durability (operating cycles, typ.)5 000 000
Durability with aux. switch block (cycles, typ.)5 000 000
3RT2036-3SP30 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2036-3SP30 — Mechanical
ParameterValue
Width55 mm
Height114 mm
Depth130 mm
3RT2036-3SP30 — Specifications
ParameterValue
At AC30 ... 55 ms

Product details

SIRIUS 3RT2036-3SP30 — Size S2 Power Contactor with Spring-Type Terminals

Its coil is rated for 175... 280 V AC, with a pickup threshold of 0.8 x rated value and a dropout margin of 1.1 x full-scale value. The main contacts are terminated with spring-type terminals (cage-clamp style), accepting 2x (0.5... 2.5 mm²) solid or stranded conductors. That saves a good five minutes per connection versus screw terminals on a panel build, and the vibration resistance is better — no re-torque on commissioning. The mounting position allows +/-180° rotation on a vertical surface and can be tilted forward/backward by +/-22.5°, so you can fit it into tight enclosures without worrying about orientation derating — just keep the ambient within -25... +60 °C during operation and -55... +80 °C during storage.

Auxiliary Contact Block and Switching Performance

This variant includes an integrated auxiliary switch block with 1 N/O + 1 N/C configuration (18... 1 contacts per the ordering code). The auxiliary contacts are rated for 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, and 0.9 A at 125 V — these are the DC ratings, so if you're switching a 24 VDC PLC input, you have headroom; at 125 VDC you're near the limit, so factor in the load type. Arcing time is 10... 20 ms, and the contactor can handle up to 1 000 switching cycles per hour at AC-1 (resistive load), 800 at AC-3 (motor starting), and 250 at AC-4 (plugging/inching). The AC-3e rating matches the AC-3 figure at 800 1/h, so for standard squirrel-cage motor duty you're well within the mechanical life of 5 000 000 operations typical. Inrush current peak is 43 A — that's the coil inrush, not the main contacts. The coil draw is 2 VA at both 50 Hz and 60 Hz, so the control transformer sizing is straightforward: a 50 VA transformer can drive about 25 of these contactors simultaneously.

Frequently asked questions

What is the MTBF of 3RT2036-3SP30?

The listed MTBF is 52 a, which is a solid figure for a Size S2 contactor.

What is the coil voltage range for 3RT2036-3SP30?

The coil is rated 175... 280 V AC, with a pickup threshold of 0.8 x rated value and a dropout margin of 1.1 x full-scale value.