Skip to main content
Siemens 3RT2036-3XJ40-0LA2 — Contactors

Siemens SIRIUS 3RT2036-3XJ40-0LA2 Contactor, 52 A at 480/600

MPN3RT2036-3XJ40-0LA2
Active

Siemens SIRIUS contactor, size S2, 3RT2036-3XJ40-0LA2, DC-operated coil 72 V, 52 A rated at 480 V / 600 V, spring-type terminals, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2036-3XJ40-0LA2 — Identification
ParameterValue
Contactor frame sizeS2
3RT2036-3XJ40-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2036-3XJ40-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2036-3XJ40-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT2036-3XJ40-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2036-3XJ40-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2036-3XJ40-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2036-3XJ40-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2036-3XJ40-0LA2 — Mechanical
ParameterValue
Width55 mm
Height114 mm
Depth130 mm

Product details

Product Overview and Key Ratings

The coil is DC-operated with a rated value of 72 V, and the contactor features an extended operating range for reliable pick-up under varying control voltage conditions.

For panel layout planning, the dimensions are 55 mm width, 114 mm height, and 130 mm depth. The main contacts accept solid or stranded wire: 2x (0.5... 2.5 mm²).

Switching Capacity and Duty Ratings

The contactor's switching capacity is specified per voltage for DC-1 or similar resistive/inductive loads. At 24 V it switches 6 A; at 48 V and 60 V, 2 A; at 110 V, 1 A; at 125 V, 0.9 A; at 220 V, 0.3 A; at 400 V, 3 A; at 500 V, 2 A; at 690 V, 1 A. For motor duty at 230 V, it is rated 10 hp. The AC-4 maximum switching rate is 250 operations per hour. Mechanical endurance is typical 10,000,000 operations. Arcing time is 10... 20 ms.

Frequently asked questions

What are the key dimensions of this contactor?

Width 55 mm, height 114 mm, depth 130 mm. Required clearances: 10 mm upwards, forwards, and downwards; 6 mm at the side.

What is the rated current at 480 V and 600 V?

52 A at both 480 V and 600 V, making it suitable for motor circuits up to that current level.

Does this contactor include an auxiliary switch?

No, the standard configuration does not include an auxiliary switch. Auxiliary contact blocks are available separately if needed.

MPN
3RT2036-3XJ40-0LA2