Skip to main content
Siemens 3RT2036-3XJ44-0LA2 — Contactors

Siemens 3RT2036-3XJ44-0LA2 SIRIUS Contactor, 55 mm, Spring-T

MPN3RT2036-3XJ44-0LA2
Active

Siemens SIRIUS S2 contactor, 3RT2036-3XJ44-0LA2, DC coil with extended operating range, spring-type terminals, 55 mm width, 178 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2036-3XJ44-0LA2 — Identification
ParameterValue
Contactor frame sizeS2
3RT2036-3XJ44-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2036-3XJ44-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2036-3XJ44-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT2036-3XJ44-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2036-3XJ44-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2036-3XJ44-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2036-3XJ44-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2036-3XJ44-0LA2 — Mechanical
ParameterValue
Width55 mm
Height114 mm
Depth178 mm

Product details

The Siemens 3RT2036-3XJ44-0LA2 is a SIRIUS S2-size contactor with a DC coil featuring an extended operating range, terminated with spring-type terminals. The DC coil's extended operating range means it holds in across a wider voltage band than a standard coil — useful on lines with saggy 24 VDC supplies or long cable runs.

Mounting & Panel Fit

Width of 55 mm and depth of 178 mm; height is 114 mm.

Coil & Switching Performance

Rated coil voltage is 72 V DC. Switching times: DC closing time 30...55 ms, arcing time 10...20 ms. The contactor is rated for AC-4 duty at 250 operations per hour maximum — that's the plugging/reversing/inching duty class, so it handles frequent jogging on a conveyor or hoist. At 24 V DC the rated operational current for the main contacts is 6 A; at 48 V DC it's 2 A; at 110 V DC it's 1 A; at 220 V DC it's 0.3 A. These DC ratings are for resistive loads — if you're switching DC motors or solenoids, derate further or add a flyback diode.

Environmental & Mechanical Life

The contactor is rated for 10,000,000 mechanical operations typical, so it outlasts the machine in most cyclic applications.

Frequently asked questions

What is the closest functional alternative to 3RT2036-3XJ44-0LA2?

The closest peer is the 3RT2037-1AL20-ZX95, which is also an S2-frame contactor but with a standard AC coil and screw terminals rather than the DC extended-range coil and spring terminals on this unit. Panel footprint is the same 55 mm width and 178 mm depth, so it drops into the same DIN rail slot without rewiring the main power circuit — but the coil circuit and termination method differ, so verify your control voltage and wiring preference before substituting.

Where can I buy 3RT2036-3XJ44-0LA2 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for your target quantity and delivery window.

Will 3RT2036-3XJ44-0LA2 drop into a panel built for 3RT2037-1AL20-ZX95?

Yes, the mounting footprint is identical — both are S2 size, 55 mm wide, 178 mm deep, and snap onto 35 mm DIN rail. The main power connections land in the same positions. However, the coil is DC with spring terminals on this unit versus AC with screw terminals on the 3RT2037-1AL20-ZX95, so the control wiring and coil supply must be adapted.

What compliance documentation is available for 3RT2036-3XJ44-0LA2?

As a Siemens SIRIUS product, it carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 for contactors. RoHS and REACH declarations are standard from Siemens for this series. Specific UL/CSA file numbers should be confirmed against the nameplate marking on the unit you receive.

MPN
3RT2036-3XJ44-0LA2