That's handy when you're shoehorning this into a crowded panel and the rail isn't perfectly straight. Dimensions: 114 mm high, 55 mm wide, 130 mm deep. That 130 mm depth means it'll sit deep in a 200 mm enclosure, but check your gland plate clearance if you're back-to-back with another row.
The headline number is 65 A at 480 V in AC-3 duty — that's the motor-switching current, not the resistive load. For resistive loads (AC-1), the switching rate maxes out at 800 cycles per hour; for AC-3 motor starts, it's 700 per hour. AC-4 (plugging/reversing) drops to 200 per hour. The coil draws 0.36 A at 50 Hz and 0.39 A at 60 Hz. For DC switching: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.6 A at 440 V. The auxiliary switch is included — no add-on module needed for basic status feedback.