Siemens 3RT2037-1AV60 SIRIUS Power Contactor, 480V 65A AC-3

MPN3RT2037-1AV60
Active

Siemens SIRIUS power contactor, size S2, 3RT2037-1AV60, 65 A AC-3 at 480 V 60 Hz, screw-type coil terminals, 24 V 60 Hz coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT2037-1AV60 — Identification
ParameterValue
Contactor frame sizeS2
3RT2037-1AV60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2037-1AV60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT2037-1AV60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2037-1AV60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 125A (690V,100kA), aM: 63A (690V,100kA), BS88: 100A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2037-1AV60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2037-1AV60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2037-1AV60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2037-1AV60 — Mechanical
ParameterValue
Width55 mm
Height114 mm
Depth130 mm
3RT2037-1AV60 — Specifications
ParameterValue
At AC10 ... 18 ms

Product details

Siemens 3RT2037-1AV60 — SIRIUS Size S2 Power Contactor

Its headline rating is 65 A at 480 V 60 Hz under AC-3 duty — the standard category for squirrel-cage motor starting, so it handles the locked-rotor inrush and breaks the running current for motors up to that frame size. The 24 V 60 Hz coil draws 0.37 A holding power at 60 Hz, which keeps the control transformer sizing straightforward.

The AC-3 rating of 65 A at 480 V is the number that governs motor switching — it means the contactor can make and break the motor's running current under full load. For resistive loads (AC-1), the maximum operating frequency is 800 switching cycles per hour, while AC-3 allows 700 cycles per hour. AC-4 (plugging/inching) drops to 200 cycles per hour, reflecting the higher electrical stress of reversing duty. The built-in auxiliary switch provides 1 normally open and 1 normally closed contact (18...1 configuration). Those aux contacts carry rated currents from 10 A at 24 V down to 0.3 A at 220 V — useful for status feedback to a PLC or for interlocking in a reversing starter. The screw-type coil terminals accept 2x (0.5...1.5 mm²) or 2x (0.75...2.5 mm²) solid or stranded wire.

Dimensions and Panel Clearance

The contactor measures 114 mm high, 55 mm wide, and 130 mm deep. The arcing time is 10...20 ms, and the closing time is 10...18 ms — both within the normal range for this frame class.

The lifecycle status is current production, so this is an active catalog item — not a phase-out or NRND part.

Frequently asked questions

Where can I buy 3RT2037-1AV60 and get a price?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a landed-cost quote.

What are the key ratings of 3RT2037-1AV60?

The headline rating is 65 A at 480 V 60 Hz under AC-3 motor duty. The coil is 24 V 60 Hz, drawing 0.37 A holding. Built-in auxiliary contacts: 1 NO + 1 NC, rated from 10 A at 24 V down to 0.3 A at 220 V.

Will 3RT2037-1AV60 drop into a panel specified around 3RT2024-1AL20-ZX95?

Both are SIRIUS size S2 contactors on the same DIN-rail footprint, so the mounting and bus-bar spacing are identical. The main difference is the current rating — the 3RT2037-1AV60 is a higher-rated unit (65 A AC-3 vs the 3RT2024's lower rating), so verify the motor FLA and upstream protection before substitution.