Siemens 3RT2038-3AP06 — Contactors

Siemens 3RT2038-3AP06 SIRIUS Contactor, 65 A at 480 V

MPN3RT2038-3AP06
Active

Siemens SIRIUS 3RT2038-3AP06 power contactor, S2 frame, 65 A at 480 V AC-3, 3-pole, screw and snap-on mounting onto 35 mm DIN rail, spring-type terminals.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT2038-3AP06 — Identification
ParameterValue
Contactor frame sizeS2

Ratings & Performance

3RT2038-3AP06 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V15 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT2038-3AP06 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.37
Rated value @ 50 Hz230 V

Contacts & Poles

3RT2038-3AP06 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT2038-3AP06 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160A (690V,100kA), aM: 80A (690V,100kA), BS88: 125A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT2038-3AP06 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes

Durability

3RT2038-3AP06 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000

Environmental

3RT2038-3AP06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT2038-3AP06 — Mechanical
ParameterValue
Width75 mm
Height114 mm
Depth130 mm

Specifications

3RT2038-3AP06 — Specifications
ParameterValue
At AC10 ... 18 ms

Product details

65 A at 480 V — the number that decides the motor load

The 3RT2038-3AP06 is rated 65 A at 480 V in AC-3 duty, which is the motor-switching rating that governs the real-world load it can handle — not the AC-1 resistive rating, which would be higher. For a 480 V motor drawing 65 A full-load, this contactor sits right at the nameplate, so you'd typically step up one frame for headroom if the application cycles hard. It's part of the SIRIUS family, Siemens' standard power contactor line, and the S2 frame size tells you the mechanical interlock and accessory kit it takes — that matters when you're building a reversing or star-delta starter.

DIN-rail fit and panel space

Width is 75 mm, depth 130 mm, height 114 mm — that 75 mm width is three 25 mm module slots on a standard DIN rail, so when you're laying out a panel, this contactor eats three positions. Skimp on these and you risk tracking or restricted heat dissipation.

Switching frequency and coil draw

Maximum operating cycles per hour: 700 at AC-1, 500 at AC-3, 350 at AC-2, 150 at AC-4. For a motor starting application, the AC-3 ceiling of 500 operations/hour is the one to watch — that's about 8 starts per minute, which is fine for most conveyors and pumps but tight for high-cycle stamping or indexing. If you're driving this from a PLC output, make sure the output can handle that surge; a typical 24 VDC digital output at 0.5 A continuous won't cut it without an interposing relay.

Termination and wiring

No screw tightening, no torque spec to verify, which saves time on a panel build. The auxiliary switch is listed as 'No', meaning this variant ships without factory-fitted aux contacts — you add them separately if needed.

Frequently asked questions

What is the 3RT2038-3AP06 used for?

It's a power contactor for switching motor loads — typically conveyors, pumps, fans, and compressors in industrial control panels. The 65 A AC-3 rating at 480 V matches it to motors drawing up to that full-load current.

What are the key ratings of the 3RT2038-3AP06?

The headline rating is 65 A at 480 V in AC-3 duty. The coil draws 6 A at 24 V pickup. Maximum switching frequency is 500 operations per hour in AC-3. Mechanical life is 10 million cycles typical.

How can I order the 3RT2038-3AP06 or check availability?

This contactor is sourced to order through independent distribution. No stock-holding claim is made here — it's quoted per your BOM.