Skip to main content
Siemens 3RT2045-1AL26 — Contactors

Siemens 3RT2045-1AL26 SIRIUS Power Contactor, S3 Frame, 80 m

MPN3RT2045-1AL26
Active

Siemens SIRIUS power contactor, 3RT2045-1AL26, S3 frame size, 80 mm width, screw and snap-on mounting on 35 mm DIN rail per DIN EN 60715, with auxiliary switch, screw-type coil terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2045-1AL26 — Identification
ParameterValue
Contactor frame sizeS3
3RT2045-1AL26 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V15 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2045-1AL26 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.35
Rated value @ 50 Hz230 V
3RT2045-1AL26 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2045-1AL26 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160A (690V,100kA), aM: 80A (690V,100kA), BS88: 125A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2045-1AL26 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2.5 ... 16 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2045-1AL26 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2045-1AL26 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2045-1AL26 — Mechanical
ParameterValue
Width80 mm
Height140 mm
Depth152 mm
3RT2045-1AL26 — Specifications
ParameterValue
At AC10 ... 21 ms

Product details

Siemens 3RT2045-1AL26 — SIRIUS Power Contactor, S3 Frame

The contactor measures 80 mm wide by 140 mm high by 152 mm deep, fitting standard panel layouts with clearance requirements of 10 mm upwards, 20 mm forwards, 10 mm downwards, and 10 mm at the side. It accepts solid conductors from 2.5 to 16 mm² and stranded conductors from 6 to 70 mm², with fine-stranded capacity for 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²). The main contacts are configured as 10 normally open and 2 normally closed, and the contactor is rated for mechanical service life of 10,000,000 operations typical.

Duty Class and Switching Frequency

Switching frequency varies by duty class: AC-1 (resistive) maximum 900 cycles/h, AC-2 (slip-ring motor) maximum 400 cycles/h, AC-3 (squirrel-cage motor starting) maximum 1,000 cycles/h, AC-3e (enhanced AC-3) also 1,000 cycles/h, and AC-4 (plugging/inching) maximum 300 cycles/h. Operating time is 10 to 21 ms at AC, with arcing time of 10 to 20 ms. Power factor is 0.35 at 50 Hz and 0.41 at 60 Hz.

Auxiliary Contact Ratings and Environmental Range

The auxiliary switch is rated for 6 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.8 A at 440 V.

Frequently asked questions

What are the key dimensions of 3RT2045-1AL26 for panel layout?

The contactor measures 80 mm wide, 140 mm high, and 152 mm deep. Required clearances are 10 mm upwards, 20 mm forwards, 10 mm downwards, and 10 mm at the side.

What conductor sizes does 3RT2045-1AL26 accept?

It accepts solid conductors from 2.5 to 16 mm² and stranded conductors from 6 to 70 mm². For fine-stranded wire, it accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²).

How do I get current pricing and availability for 3RT2045-1AL26?

Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront for a current quote on this part.

What is the AC-3 switching frequency for this contactor?

The maximum switching frequency in AC-3 duty (squirrel-cage motor starting) is 1,000 cycles per hour.

MPN
3RT2045-1AL26