Siemens 3RT2045-1AP04-3MA0 — Contactors

Siemens 3RT2045-1AP04-3MA0 SIRIUS Power Contactor, 77 A at 4

MPN3RT2045-1AP04-3MA0
Active

Siemens SIRIUS 3RT2045-1AP04-3MA0 power contactor, Size S3, screw-type coil terminals, auxiliary switch, 77 A rated operational current at 480 V AC-3, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2045-1AP04-3MA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT2045-1AP04-3MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V15 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2045-1AP04-3MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.38
Rated value @ 50 Hz230 V
3RT2045-1AP04-3MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2045-1AP04-3MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160A (690V,100kA), aM: 80A (690V,100kA), BS88: 125A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2045-1AP04-3MA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2.5 ... 16 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2045-1AP04-3MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2045-1AP04-3MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2045-1AP04-3MA0 — Mechanical
ParameterValue
Width70 mm
Height140 mm
Depth195 mm
3RT2045-1AP04-3MA0 — Specifications
ParameterValue
At AC10 ... 21 ms

Product details

The 3RT2045-1AP04-3MA0: AC-3 switching frequency maxes at 1 000 operations per hour; AC-4 drops to 300/h — that's the plugging/inching duty cycle limit, so for high-cycle reversing applications you need to stay under 300 ops/h or derate. AC-1 resistive load allows 900 ops/h. Arcing time sits at 10 to 20 ms, with a 50 Hz arcing factor of 0.38 — that's the time the arc extinguishes per half-cycle, relevant for coordination with upstream fuses or MCCBs.

Wiring and clearance

Main power terminals accept solid wire 2.5 to 16 mm² or stranded 6 to 70 mm² — that covers most motor feeds up to 77 A. Auxiliary terminals take 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). Minimum clearance: 10 mm upwards, 10 mm downwards, 10 mm at the side, 20 mm forwards — a standard 70 mm wide by 140 mm tall by 195 mm deep footprint.

MPN
3RT2045-1AP04-3MA0