Skip to main content
Siemens 3RT2046-1KB40 — Contactors

Siemens 3RT2046-1KB40 SIRIUS Contactor, 24 VDC Coil

MPN3RT2046-1KB40
Active

Siemens SIRIUS coupling contactor 3RT2046-1KB40, S3 frame, 24 VDC coil, screw-type terminals, 70 x 140 x 152 mm DIN-rail mount.

$218.07Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2046-1KB40 — Identification
ParameterValue
Contactor frame sizeS3
3RT2046-1KB40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V80 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V20 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2046-1KB40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2046-1KB40 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2046-1KB40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2046-1KB40 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2.5 ... 16 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2046-1KB40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2046-1KB40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2046-1KB40 — Mechanical
ParameterValue
Width70 mm
Height140 mm
Depth152 mm
3RT2046-1KB40 — Specifications
ParameterValue
At AC16.3g / 5 ms, 10.g / 10 ms

Product details

SIRIUS S3 Coupling Contactor — 24 VDC Coil

The 24 VDC coil draws a 2.7 A inrush peak, then holds at the rated coil voltage — compatible with standard 24 VDC PLC outputs when the inrush is within the output's short-circuit current rating. Rated for AC-3 switching at 850 operations per hour, this contactor handles the typical motor starting duty cycle for conveyors, pumps, and fans. The AC-3e rating matches the same 850 1/h ceiling, reflecting the IEC 60947-4-1 standard for motor switching.

DIN-Rail Mount & Wiring Clearances

The 70 mm width, 140 mm height, and 152 mm depth fit standard panel layouts — allow 10 mm clearance upwards, 10 mm downwards, 20 mm forwards, and 10 mm at the side for heat dissipation and arc flash. Power wiring accepts 2.5 to 16 mm² solid conductors on the main contacts, and 6 to 70 mm² stranded — covering most motor circuit sizes up to the S3 frame rating. The magnet coil uses screw-type terminals.

Switching Performance & Coil Data

Arcing time runs 10 to 20 ms, with a DC make/break time of 38 to 57 ms — the contactor closes firmly before the arcing extinguishes. Shock resistance is 16.3g at 5 ms and 10g at 10 ms under AC conditions, suitable for industrial environments with moderate vibration. The coil operates at 24 VDC with a pick-up threshold of 0.8× rated value and a dropout of 1.2× full-scale value. Inrush current peaks at 2.7 A, then settles to the holding current — the 24 VDC coil is directly drivable from a PLC output if the output can handle the inrush transient.

Frequently asked questions

What is the difference between AC-3 and AC-3e on this contactor?

Both are rated at 850 operations per hour maximum on the 3RT2046-1KB40. AC-3e is the IEC 60947-4-1 enhanced motor switching category with slightly different test conditions; for practical motor starting duty, the two ratings are interchangeable.

MPN
3RT2046-1KB40