Skip to main content
Siemens 3RT2046-1NB34 — Contactors

Siemens 3RT2046-1NB34 SIRIUS Power Contactor, S3, 70 mm

MPN3RT2046-1NB34
Active

Siemens SIRIUS 3RT2046-1NB34 power contactor, S3 frame size, 70 mm width, screw-type coil terminals, 6.5 A inrush peak, screw and snap-on 35 mm DIN rail mounting.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT2046-1NB34 — Identification
ParameterValue
Contactor frame sizeS3

Ratings & Performance

3RT2046-1NB34 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V80 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V20 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT2046-1NB34 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz3.5 VA
Rated value @ 50 Hz20 ... 33 V

Contacts & Poles

3RT2046-1NB34 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT2046-1NB34 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT2046-1NB34 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2.5 ... 16 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes

Durability

3RT2046-1NB34 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000

Environmental

3RT2046-1NB34 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT2046-1NB34 — Mechanical
ParameterValue
Width70 mm
Height140 mm
Depth195 mm

Specifications

3RT2046-1NB34 — Specifications
ParameterValue
At AC38 ... 57 ms

Product details

S3 frame, 70 mm wide — panel fit first

The 3RT2046-1NB34 is a SIRIUS power contactor in the S3 frame size, 70 mm wide, 140 mm tall, 195 mm deep — the width is the dimension that governs DIN-rail spacing in a crowded enclosure. Mounting is screw-and-snap-on onto 35 mm DIN rail per DIN EN 60715, with ±180° rotation and ±22.5° tilt on a vertical surface, so it fits into retrofit panels where the rail orientation isn't ideal.

Coil drive and wiring

The magnet coil uses screw-type terminals and draws a 6.5 A inrush peak — the coil hold-in power is 3.5 VA at both 50 Hz and 60 Hz, so a 24 VDC control transformer sized for 10 A inrush handles the start surge without sag. Power wiring accepts solid conductors 2.5…16 mm² or stranded 6…70 mm²; control wiring takes 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) — no need for ferrule adapters on the main terminals for typical panel wire.

Switching duty and mechanical life

The contactor is rated for 850 operations per hour in AC-3 and AC-3e duty, 900/h in AC-1 (resistive), 350/h in AC-2, and 250/h in AC-4 — the AC-4 figure is the one to watch for plugging or inching applications; it limits the cycle rate to about four per minute. Typical mechanical life is 10 million operations, and the arcing time is 10…20 ms — the contactor is built for high-cycle conveyor or pump start-stop duty without premature weld risk.

Sourcing and lifecycle

Operating temperature range is -25…+60 °C, storage -55…+80 °C — suitable for unheated plant-floor enclosures in most climates.

Frequently asked questions

How is the 3RT2046-1NB34 quoted for volume purchases?

The contactor is quoted to order against the BOM quantity through independent industrial distribution. Volume pricing and lead time are confirmed at quote time — no stock-holding claim is made here.

MPN
3RT2046-1NB34