3RT2046-1NF34 — Identification
ParameterValue
Contactor frame sizeS3
3RT2046-1NF34 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V80 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V20 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2046-1NF34 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz3.5 VA
Rated value @ 50 Hz83 ... 155 V
3RT2046-1NF34 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2046-1NF34 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2046-1NF34 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2.5 ... 16 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2046-1NF34 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2046-1NF34 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2046-1NF34 — Mechanical
ParameterValue
Width70 mm
Height140 mm
Depth195 mm
3RT2046-1NF34 — Specifications
ParameterValue
At AC38 ... 57 ms

Product details

Siemens 3RT2046-1NF34 — SIRIUS S3 Power Contactor

It carries a coil rated at 83-155 V, drawing 3.5 VA at both 50 Hz and 60 Hz, with an inrush current peak of 1.5 A. The main contacts are screw-type terminals accepting solid conductors from 2.5 to 16 mm² and stranded from 6 to 70 mm².

Duty Ratings and Switching Frequency

Switching frequency varies by duty class: 900 operations per hour at AC-1 (resistive), 850 at AC-3 and AC-3e (squirrel-cage motor starting), 350 at AC-2 (slip-ring motor), and 250 at AC-4 (plugging/inching). The arcing time is 10-20 ms, and the operating time (both AC and DC) is 38-57 ms. These ratings define the thermal cycling limits for the contactor in a given application — AC-3 is the typical motor-switching duty, and the 850 ops/h ceiling means it handles moderate cycling on a conveyor or pump without exceeding thermal rise limits.

Auxiliary Contacts and Environmental Range

An auxiliary switch is included. Its rated values at different voltages: 6 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V. The contactor is rated for a full-scale value of 1.1 (likely the rated operational current multiplier for overload conditions) and an initial value of 0.8 (possibly the pick-up voltage threshold relative to rated).

Frequently asked questions

What is the closest functional second-source for 3RT2046-1NF34?

The 3RT1054-1AB36 is a peer in the same SIRIUS contactor family but in a different frame size (S2 vs S3). The 3RT2046-1NF34 is an S3 frame; the 3RT1054-1AB36 is an S2. Panel fit and terminal spacing differ — verify mechanical dimensions before substituting.

What wire sizes does the 3RT2046-1NF34 accept?

Solid conductors: 2.5 to 16 mm². Stranded conductors: 6 to 70 mm². Auxiliary terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²).

Will 3RT2046-1NF34 drop into a panel specified for 3RT1054-1AB36?

Not without checking mechanical fit — the 3RT2046-1NF34 is an S3 frame, while the 3RT1054-1AB36 is an S2 frame. Dimensions and DIN rail footprint differ. Verify panel cutout and terminal alignment before substituting.