Siemens 3RT2046-3AP06 — Contactors

Siemens 3RT2046-3AP06 SIRIUS Power Contactor, 96 A at 480 V

MPN3RT2046-3AP06
Active

Siemens SIRIUS 3RT2046-3AP06 power contactor, size S3, 3-pole, 96 A at 480 V AC-3, spring-type terminals, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2046-3AP06 — Identification
ParameterValue
Contactor frame sizeS3
3RT2046-3AP06 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V80 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V20 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2046-3AP06 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.38
Rated value @ 50 Hz230 V
3RT2046-3AP06 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2046-3AP06 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2046-3AP06 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2.5 ... 16 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2046-3AP06 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2046-3AP06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2046-3AP06 — Mechanical
ParameterValue
Width80 mm
Height140 mm
Depth152 mm
3RT2046-3AP06 — Specifications
ParameterValue
At AC10 ... 21 ms

Product details

What this contactor is and where it fits

The Siemens 3RT2046-3AP06 is a SIRIUS S3 power contactor — the frame size that handles the 96 A AC-3 band at 480 V, which covers most 50 hp motor loads at that voltage. It is a 3-pole unit with spring-type terminals on the coil and main contacts, so no screw torque to chase on the control wiring. Mounting is screw or snap-on onto 35 mm DIN rail per DIN EN 60715, and the mounting position allows +/-180° rotation on a vertical surface plus +/-22.5° tilt forward/backward — useful when the panel layout forces an odd angle.

Key ratings and what they mean for the panel

The headline number is 96 A at 480 V in AC-3 duty — that is the motor-switching current for squirrel-cage motors, the most common load this contactor will see. The same contactor carries 20 hp at 230 V, so it scales down cleanly for lower-voltage motor banks. Switching frequency varies by duty class: 850 operations per hour in AC-3 and AC-3e, 900 in AC-1 (resistive), 350 in AC-2 (slip-ring motor starting), and 250 in AC-4 (plugging/reversing). For a conveyor line running at 30 starts per hour, the AC-3 rating leaves headroom; for a reversing application, the AC-4 ceiling is the one to watch. Wire range is 2.5 to 16 mm² solid for the control circuit and 6 to 70 mm² stranded for the main power loop — covers everything from #10 AWG control wiring to #2/0 AWG feeder on the line side. Dimensions are 140 mm high, 80 mm wide, 152 mm deep — the S3 footprint fits a standard 200 mm deep enclosure with room for the 10 mm clearance above and below, 20 mm forward, and 10 mm sideways to adjacent devices.

Lifecycle and sourcing posture

The auxiliary switch block is available as a separate order — the contactor body ships without one fitted, so if the BOM calls for aux contacts, order them alongside.

MPN