Siemens 3RT2316-2AK60 — Contactors

Siemens 3RT2316-2AK60 SIRIUS Contactor, 4 kW AC-3, 110-120 V

MPN3RT2316-2AK60
Active

Siemens SIRIUS size S00 contactor, 3RT2316-2AK60, 4 kW AC-3 at 400 V, 9 A rated operational current, 110 VAC 50 Hz / 120 VAC 60 Hz coil, spring-loaded terminals, screw and snap-on 35 mm DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2316-2AK60 — Identification
ParameterValue
Contactor frame sizeS00
3RT2316-2AK60 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V4 kW
Rated value @ 400 V9 A
3RT2316-2AK60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2316-2AK60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
3RT2316-2AK60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 20 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2316-2AK60 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.5 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2316-2AK60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2316-2AK60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2316-2AK60 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2316-2AK60 — Specifications
ParameterValue
At AC7 ... 13 ms

Product details

The Siemens 3RT2316-2AK60 is a SIRIUS-branded contactor in the compact size S00 frame, rated for switching three-phase motor loads up to 4 kW in AC-3 duty at 400 V. The rated operational current of 9 A at 400 V confirms the continuous thermal capacity for the main circuit. The coil is wound for AC control: 110 V at 50 Hz, 120 V at 60 Hz, with a typical pickup VA of 0.24 at both frequencies. That 0.24 VA holding power means the control transformer or PLC relay driving it sees negligible steady-state load — useful when multiple contactors share a single 24 VDC-to-AC interface relay. Spring-loaded terminals (cage-clamp style) on the main current circuit accept 2x 0.5–2.5 mm² solid or 0.5–4 mm² stranded conductors. No screw torque to verify, no periodic re-torquing — a time-saver during panel build and a reliability gain under vibration.

Panel Integration and Clearances

The S00 footprint is 45 mm wide, 70 mm tall, 73 mm deep — a tight fit that leaves room for a full motor starter combination in a 400 mm wide enclosure. That 6 mm side gap is the critical one when packing multiple contactors on a rail — ignore it and you lose the free air circulation the thermal derating curve expects. This matters when the panel layout forces a non-standard orientation — the contactor's mechanical life of 30 million operations (typical) assumes the specified position, but the tolerance covers most cabinet constraints.

The 60 °C ceiling is the practical limit inside a sealed cabinet with other heat sources — above that, derate the AC-3 current or add forced ventilation. Relative humidity minimum 10 %; no upper limit stated, but the spring terminals and sealed coil handle condensation cycles better than screw-clamp equivalents. Rated impulse withstand voltage of the main circuit is 6 kV, which aligns with IEC 60947-4-1 requirements for industrial motor starters. The part carries a RoHS compliance date of October 1, 2009, indicating it meets the EU RoHS directive for the substance prohibitions in effect at that time.

Frequently asked questions

What is the AC-3 motor rating of the 3RT2316-2AK60?

It is rated 4 kW at AC-3 duty at 400 V, with a rated operational current of 9 A at 400 V. That 4 kW figure is the motor power class it can switch reliably.

What coil voltage does the 3RT2316-2AK60 use?

The coil is AC-operated: 110 V at 50 Hz and 120 V at 60 Hz. Holding power is 0.24 VA at both frequencies.

What type of terminals does the 3RT2316-2AK60 have?

Spring-loaded terminals (cage-clamp) on the main current circuit, accepting 2x 0.5–2.5 mm² solid or 0.5–4 mm² stranded conductors. The coil connection uses spring-type terminals as well.

Will the 3RT2316-2AK60 drop into a panel specified around the 3RT2015-2AP01?

Both are size S00 contactors on the same 45 mm DIN-rail footprint, so the mechanical fit and rail spacing are identical. The key difference is the coil voltage: the 3RT2015-2AP01 uses a 24 VDC coil, while the 3RT2316-2AK60 uses 110 VAC (50 Hz) / 120 VAC (60 Hz). Verify the control circuit voltage before swapping — the wiring to the coil terminals will need to match the new AC coil.

Where can I buy the 3RT2316-2AK60?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — no stock count is published here, but the supply channel is active.