Skip to main content
Siemens 3RT2316-2BF40 — Contactors

Siemens 3RT2316-2BF40 SIRIUS Contactor, 110 VDC Coil

MPN3RT2316-2BF40
Active

Siemens SIRIUS contactor, size S00, 3RT2316-2BF40, 110 VDC coil, 4 kW AC-3 at 400 V, spring-loaded terminals, 45 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2316-2BF40 — Identification
ParameterValue
Contactor frame sizeS00
3RT2316-2BF40 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V4 kW
Rated value @ 400 V9 A
3RT2316-2BF40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2316-2BF40 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
3RT2316-2BF40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 20 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2316-2BF40 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.5 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2316-2BF40 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2316-2BF40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2316-2BF40 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm

Product details

The Siemens 3RT2316-2BF40 is a SIRIUS contactor in size S00, built for switching three-phase motor loads up to 4 kW in AC-3 duty at 400 V — that's a 9 A rated operational current at that voltage. The coil is 110 VDC, with a pickup threshold of 0.8 x rated value (88 VDC) and a dropout floor of 1.1 x rated value (121 VDC), so it holds in cleanly on a nominal 110 VDC control supply and drops out reliably if the voltage sags.

Mounting and wiring — what fits in the panel

The main circuit uses spring-loaded terminals (cage-clamp style), accepting solid wire 2x (0.5 to 2.5 mm²) or stranded 0.5 to 4 mm². Auxiliary contacts also use spring terminals, same wire range.

Clearance and environment

Side-by-side mounting is allowed.

Frequently asked questions

What is the coil voltage of 3RT2316-2BF40?

Critical for compatibility with the control circuit voltage.

Where can I buy 3RT2316-2BF40?

Directs buyers to reliable distributors for purchase.

Is 3RT2316-2BF40 in stock?

Stock availability influences purchasing decision and lead time.

What is the price of 3RT2316-2BF40?

Pricing is key for budget and BOM cost estimation.

What is the equivalent of 3RT2316-2BF40?

Allows substitution when preferred part is unavailable or for second sourcing.

What are the dimensions of 3RT2316-2BF40?

Ensures physical fit in panel or enclosure.

MPN
3RT2316-2BF40