Siemens 3RT2317-2AV00 — Contactors

Siemens 3RT2317-2AV00 SIRIUS Contactor, AC-3 12 A, 5.5 kW

MPN3RT2317-2AV00
Active

Siemens SIRIUS contactor, size S00, 3RT2317-2AV00, AC-3 12 A at 400 V, 5.5 kW motor rating, spring-loaded terminals, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2317-2AV00 — Identification
ParameterValue
Contactor frame sizeS00
3RT2317-2AV00 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V4 kW
Rated value @ 400 V12 A
3RT2317-2AV00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz400 V
3RT2317-2AV00 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
3RT2317-2AV00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 20 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2317-2AV00 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.5 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2317-2AV00 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2317-2AV00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2317-2AV00 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2317-2AV00 — Specifications
ParameterValue
At AC7 ... 13 ms

Product details

Termination and wiring constraints

The 3RT2317-2AV00: Main current circuit uses spring-loaded terminals; the magnet coil also terminates with spring-type terminals. Solid wire accepts 2x (0.5 to 2.5 mm²); stranded accepts 0.5 to 4 mm². For both main and auxiliary contacts, the AWG range is 20 to 12.

Frequently asked questions

What wire sizes does the spring-loaded terminal accept?

Solid wire: 2x (0.5 to 2.5 mm²); stranded wire: 0.5 to 4 mm². AWG range for main and auxiliary contacts is 20 to 12.

What compliance documentation does Siemens provide for 3RT2317-2AV00?

The part carries a RoHS substance prohibition date of 10/01/2009. Operating temperature range is -25 to +60 °C; storage range is -55 to +80 °C.