Siemens 3RT2325-1AC20 — Contactors

Siemens 3RT2325-1AC20 SIRIUS S0 Contactor, 24 V AC Coil

MPN3RT2325-1AC20
Active

Siemens SIRIUS S0 contactor 3RT2325-1AC20, 24 V AC 50/60 Hz coil, 16-8 A main contact rating, screw-type terminals, screw and snap-on DIN rail mounting.

$138.62Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2325-1AC20 — Identification
ParameterValue
Contactor frame sizeS0
3RT2325-1AC20 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V7.5 kW
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2325-1AC20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz24 V
3RT2325-1AC20 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2325-1AC20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 20 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2325-1AC20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2325-1AC20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2325-1AC20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2325-1AC20 — Mechanical
ParameterValue
Width60 mm
Height85 mm
Depth97 mm
3RT2325-1AC20 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

Active SIRIUS S0 — 24 V AC Coil, Screw Terminals

The 3RT2325-1AC20: Rated main contact current of 16…8 A (size S0 frame) suits motor loads in the lower fractional-horsepower range — think small pumps, fans, or conveyor drives in control panels. The 10 A auxiliary contact rating at 24 V AC and 230 V AC handles PLC input feedback or pilot-duty signalling.

DIN Rail Fit and Wiring Clearances

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. Dimensions are 97 mm deep, 60 mm wide, 85 mm high — standard S0 footprint that drops into existing panel layouts without re-spacing. Wiring clearances: 10 mm upwards, 10 mm forwards, 10 mm downwards, 6 mm at the side. Main contact terminals accept stranded wire from 1 to 10 mm²; auxiliary terminals take 2x (0.5…1.5 mm²) solid or 2x (0.75…2.5 mm²) stranded. That 10 mm² main terminal capacity covers most S0 motor branch circuits without needing a ferrule.

Nacelle-Ready Temperature Range and Life

Rated for operation from -25 to +60 °C and storage from -55 to +80 °C — wide enough for unheated enclosures in wind turbine nacelles or outdoor industrial shelters. The 10 million typical mechanical cycles mean this contactor outlasts many downstream loads before the armature wears. Mounting position is flexible: ±180° rotation on a vertical surface, plus ±22.5° tilt forward/backward. That helps when the panel layout is tight and the contactor has to sit at an angle to clear gland plates or busbars.

Coil Inrush and Control Transformer Sizing

Coil inrush current is 0.25 A at 50 Hz and 0.28 A at 60 Hz — a 24 V AC control transformer sized for 0.5 A per contactor gives headroom for the inrush without voltage sag that could cause the contactor to drop out during pick-up. Arcing time is 10…10 ms at AC (tightly controlled), with a break time of 4…16 ms. These switching times are consistent enough for coordination with upstream motor-protective breakers in a Type 1 or Type 2 coordination scheme.

MPN
3RT2325-1AC20